Quantitative T2 mapping offers a unique contrast for detailed brain imaging. At ultra-high field strengths (7 T), the higher signal to noise ratio (SNR) enables higher spatial resolution and the delineation of smaller structures. The translation of multi-echo spin-echo-based acquisitions to higher field strength, however, is complicated by inhomogeneities in the radio frequency (RF) transmit field resulting in stronger stimulated echoes and multi-echo refocusing pathways. The T2 decay will thus depend on the specific sequence details and other experimental properties. The signal can be modeled by Bloch equation simulations to create a dictionary of possible signal patterns to fit the experimental data and estimate T2 Particularly at smaller voxel sizes and shorter T2 times, noise will affect the dictionary matching of the data by the introduction of a bias in the acquired signal magnitude dependent on the SNR. This study aims to develop a robust, accurate and fast T2 mapping approach at 7 T, addressing RF inhomogeneity and noise bias. We employed a 2D multi-echo spin-echo sequence combined with a Bloch equation simulation aided dictionary matching technique. The method incorporated a pre-measured B1+ map for regularization of the dictionary fit and applied a patch-based PCA denoising algorithm with magnitude bias correction to mitigate noise-induced errors. The method was tested in simulations, phantom validations, and in five human participants. In vivo, (0.7mm)3 isotropic high resolution T2 maps showed detailed contrast within cortical and subcortical areas. Notably, regions with high iron content, such as the substantia nigra or nucleus ruber, were distinctly visible. The proposed method provided consistent T2 values across different brain regions that aligned well with the literature where available. Simulations and experiments demonstrated the importance of the noise correction to achieve high quality maps. The proposed method can significantly contribute to studies on brain microstructure and pathology, since it produces reliable T2 maps at high resolution.

This content is only available as a PDF.
This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International (CC BY 4.0) license, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. For a full description of the license, please visit https://creativecommons.org/licenses/by/4.0/legalcode.

Article PDF first page preview

First page of High resolution quantitative T<sub>2</sub> mapping of the human brain at 7 T using a multi-echo spin-echo sequence and dictionary-based modeling

Supplementary data