A novel method for fast and high-resolution metabolic imaging, called ECcentric Circle ENcoding TRajectorIes for Compressed sensing (ECCENTRIC), has been developed at 7 Tesla MRI. ECCENTRIC is a non-Cartesian spatial-spectral encoding method designed to accelerate magnetic resonance spectroscopic imaging (MRSI) with high signal-to-noise at ultra-high field. The approach provides flexible and random sampling of the Fourier space without temporal interleaving to improve spatial response function and spectral quality. ECCENTRIC enables the implementation of spatial-spectral MRSI with reduced gradient amplitudes and slew-rates, thereby mitigating electrical, mechanical, and thermal stress of the scanner hardware. Moreover, it exhibits robustness against timing imperfections and eddy-current delay. Combined with a model-based low-rank reconstruction, this approach enables simultaneous imaging of up to 14 metabolites over the whole brain at 2–3 mm isotropic resolution in 4–10 min. MRSI ECCENTRIC was performed on four healthy volunteers, yielding high-resolution spatial mappings of neurochemical profiles within the human brain. This innovative tool introduces a novel approach to neuroscience, providing new insights into the exploration of brain activity and physiology.

Magnetic Resonance Spectroscopic Imaging (MRSI) is a well-established molecular MR imaging modality, facilitating non-invasive exploration of in vivo metabolism in both human and animal models without the use of ionizing radiation. In particular, 1H-MRSI can simultaneously image up to 20 brain metabolites, providing quantification of steady-state concentrations (Maudsley et al., 2020) and the dynamic change of concentrations under functional tasks (Bednarik et al., 2023; Mullins, 2018). In addition to measuring intrinsic metabolism without the need of contrast agents, MRSI can probe metabolic enzymatic rates that are not accessible by nuclear imaging techniques such as PET and SPECT (Davis et al., 2020). Many studies demonstrated significant value of MRSI for neuroscience (Oz et al., 2014), but the performance of current MRSI is severely lacking behind other MRI methods, which limits its use and wider adoption.

Among MRI modalities, MRSI is positioned to benefit the most from ultra-high field (UHF 7T) due to increased spectral dispersion and signal-to-noise ratio (SNR). MRSI using very short echo-time (1 ms) free induction decay (FID) excitation (Boer et al., 2012; Bogner et al., 2012; Henning et al., 2009) has great potential for metabolite imaging due to its high SNR. Nevertheless, MRSI is hampered by significant limitations, including low resolution and long scan times required for acquiring the 4D(k,t) spatial-temporal space (Bogner et al., 2021). This highlights a pressing demand for acceleration strategies in high-resolution MRSI to overcome these challenges. This is especially pertinent in the context of high-resolution whole-brain MRSI, where conventional phase-encoding acquisition schemes would require scan time as long as several hours. Acceleration of UHF MRSI has been shown by parallel imaging such as SENSE, GRAPPA, and CAIPIRINHA with uniform undersampling (Hangel et al., 2018; Nassirpour, Chang, & Henning, 2018b; Strasser et al., 2017), or by Compressed Sensing (CS) with random undersampling (Nassirpour, Chang, Avdievitch, & Henning, 2018). However, similar to MRI, these techniques, as for MRI, generally do not allow acceleration factors (AF) above 6–10 for MRSI. Additionally, spatial-spectral encoding (SSE) techniques introduce additional prospects for accelerating UHF MRSI as demonstrated by Otazo et al. (2006). By combining spatial-spectral encoding with undersampling, higher accelerations (AF>50) of UHF MRSI can be achieved (Ma et al., 2016; Moser et al., 2019; Saucedo et al., 2021).

So far, SSE has been demonstrated at ultra-high fields using either Cartesian (echo-planar) (An et al., 2018; Nam et al., 2022; Weng et al., 2022) and non-Cartesian (spirals, rosettes, concentric circles) (Chiew et al., 2018; Esmaeili et al., 2021; Hingerl et al., 2020; Moser et al., 2019) k-space trajectories.

Nonetheless, integrating SSE at ultra-high field (UHF) presents formidable challenges stemming from the inverse relationship between the maximum time allocated for a trajectory repetition and the desired spectral bandwidth (SBW). This difficulty is accentuated at higher spatial resolutions in UHF, where trajectories must cover extensive k-space while maintaining even faster repetition rates for larger SBW at UHF. Consequently, this imposes significant technical demands on the gradient system in terms of amplitude and slew rate. The employment of temporal interleaving presents a viable strategy to overcome this constraint, facilitating the achievement of broad spectral bandwidth and high spatial resolution for circle or spiral trajectory (Adalsteinsson et al., 1998; Hingerl et al., 2018; Matsui et al., 1985). For echo-planar trajectory, achieving high SBW can be achieved by interlaced Fourier transform (Ebel et al., 2005) and interleaved readout gradients with alternating polarity (An et al., 2018; Posse et al., 2007). Nevertheless, these approaches concurrently prolong the acquisition duration and might introduce spectral side-bands that degrade the signal-to-noise ratio (SNR) and interfere with metabolite spectra. This issue arises if the number of temporal interleaves and the SBW are not optimally selected to prevent side-bands from appearing within the frequency range of interest (Bogner et al., 2021). Additionally, dedicated hardware, such as gradient inserts, allows circumvention of limitations on SBW (Versteeg et al., 2024).

In this study, we introduce ECCENTRIC method (ECcentric Circle ENcoding TRajectorIes for Compressed sensing) that benefits from: 1) improved pseudo-random sampling for CS with non-Cartesian trajectories, 2) flexible sampling of the 4D (k,t) space for optimal SNR, 3) low-rank reconstruction for dimensionality reduction and denoising of data, and 4) reduced demand on the gradient system for spectral quality. Traditional trajectory designs, as mentioned above, often struggle to achieve high-resolution SSE MRSI at UHF without using temporal interleaving. To address this limitation, we designed the ECCENTRIC sampling pattern with smaller-sized circles. These circles, with their reduced radius, require lower gradient amplitude and slew rate compared to trajectories spanning the entire k-space, for identical spatial resolution and SBW. Given the upper limit in gradient amplitude and slew rate, ECCENTRIC is therefore advantageous as it allows for higher spatial resolution and/or SBW than established trajectories before reaching the gradient hardware limits, thereby avoiding the need for temporal interleaving.

The performance of the new acquisition-reconstruction scheme was first investigated by simulations and in a structural-metabolic phantom, and subsequently evaluated in vivo in healthy subjects.

Circular trajectories, including rosettes and concentric circles, provide several advantages over spiral and echo-planar trajectories in MRSI and MRI (Adalsteinsson et al., 1998; Furuyama et al., 2012; Posse et al., 1994; Schirda et al., 2018). By design, ECCENTRIC’s circular trajectories need smaller diameter than rosettes and concentric circles, which help achieve high-resolution and large spectral bandwidth at ultra-high field without temporal interleaving. ECCENTRIC trajectories are produced by readout gradient wave-forms that: 1) do not need rewinding which eliminates dead-time and the associated loss in SNR per unit time, 2) permit high matrix sizes with limited gradient amplitude, and 3) have constant and moderate gradient slew-rate that minimizes patient nerve stimulation and is not demanding for the gradient hardware. In contrast, MRSI SSE acquisitions are characterized by high gradient amplitudes and slew rates, which can exacerbate B0 field drift (An et al., 2018) and induce eddy current artifacts (Xu et al., 2020) with echo-planar trajectories. Spiral SSE trajectories suffer from gradient imperfections and eddy currents, leading to trajectory distortions (Kim & Spielman, 2006). Similarly, concentric ring trajectories experience rotation errors due to timing delays and eddy currents, although to a lesser extent (Jiang et al., 2016). Additionally, the high demand on the gradient system often leads to temperature increases (Nam et al., 2023) and mechanical resonances (Dillinger et al., 2024).

This effect is particularly pronounced at 7T, where, for equivalent spatial resolution, the FID bandwidth is approximately doubled compared to 3T, necessitating a doubling of the gradient slew-rate for SSE encoding.

Moreover, the implementation of CS acceleration (Candes et al., 2006; Donoho, 2006) relies on two prerequisites. The first is that the signal or image exhibits sparsity in a known transform domain (Knoll, Clason, et al., 2011; Michael et al., 2007). The second is that the data are randomly undersampled, which can be achieved by random undersampling of the k-space in MRI applications. To enable the random sparse undersampling necessary for CS, we utilized a novel approach where successive circular trajectories are randomly positioned in k-space, rather than using regular patterns such as rosette, concentric, or uniformly distributed circles. The acquisition strategy of ECCENTRIC is illustrated in Figure 1. The circle centers’ polar coordinates (rc,ϕc) are chosen randomly with a uniform probability within the ranges rc[0,max(kx,ymaxR,R)] and ϕc[0,2π) (Fig. 1A). Here, R represents the circle radius, kx,ymax is the largest in-plane k-space coordinate (assuming the same spatial resolution along all axial plane directions). The majority of circles are placed randomly as shown with two successive circles (c and c+1) in the sketch Figure 1A, but with the constraint to avoid significant overlap between circles (Fig. 1B): the distance between the centers of each circle, Δ, must be larger or equal to the Nyquist distance (the inverse of the field-of-view size). When Δ<2R, there is partial overlap between circles; however, this redundant sampling is predominantly concentrated in the central region of k-space, enabling an enhancement in SNR. In addition to the random pattern, a small subset of circles (<5% of the total number) positioned in rosette fashion is acquired in the center of k-space (Fig. 1C). This ensures complete sampling of the center of k-space, which is beneficial for SNR and reconstruction performance (Knoll, Clason, et al., 2011; Michael et al., 2007) with negligible effect on acquisition time. The homogeneous random distribution of circle polar coordinates results intrinsically in a pseudo-random k-space sampling with density following 1/k outside of the rosette sampled central region.

Fig. 1.

3D ECCENTRIC sampling and acquisition. (A) Circle center positions are parameterized in polar coordinates (rc,ϕc) that are chosen randomly in the ranges rc[0,max(kx,ymaxr,r)] and ϕc[0,2π]. Two consecutive circles (c and c+1) must respect the overlap rule described in (B): the distance between their respective centers, Δ, must be greater or equal to the Nyquist distance, ΔNy. (C), to satisfy a systematic full sampling of the k-space center, a small subset (<5%) of circles is positioned in rosette pattern in each ECCENTRIC encoding planes. (D), 3D k-space sampling is achieved by a stack of ECCENTRIC encoding planes with variable kx,ymax to realize an ellipsoid coverage. (E) Diagram of the 3D ECCENTRIC FID-MRSI sequence. First, a 4-pulse WET water suppression technique is used, followed by the Shinnar–Le Roux optimized excitation pulse. After the excitation, the Cartesian encoding is performed along the z-axis, simultaneously to the gradient ramp along the x- and y-axes to reach the desired k-space off-center position and velocity. Finally, a sinusoidal gradient wave-form is applied along the x- and y-axis during acquisition to produce the circular trajectory.

Fig. 1.

3D ECCENTRIC sampling and acquisition. (A) Circle center positions are parameterized in polar coordinates (rc,ϕc) that are chosen randomly in the ranges rc[0,max(kx,ymaxr,r)] and ϕc[0,2π]. Two consecutive circles (c and c+1) must respect the overlap rule described in (B): the distance between their respective centers, Δ, must be greater or equal to the Nyquist distance, ΔNy. (C), to satisfy a systematic full sampling of the k-space center, a small subset (<5%) of circles is positioned in rosette pattern in each ECCENTRIC encoding planes. (D), 3D k-space sampling is achieved by a stack of ECCENTRIC encoding planes with variable kx,ymax to realize an ellipsoid coverage. (E) Diagram of the 3D ECCENTRIC FID-MRSI sequence. First, a 4-pulse WET water suppression technique is used, followed by the Shinnar–Le Roux optimized excitation pulse. After the excitation, the Cartesian encoding is performed along the z-axis, simultaneously to the gradient ramp along the x- and y-axes to reach the desired k-space off-center position and velocity. Finally, a sinusoidal gradient wave-form is applied along the x- and y-axis during acquisition to produce the circular trajectory.

Close modal

The ECCENTRIC design offers the flexibility to choose the radius of circles within the range of 0 to kx,ymax2. Therefore, for a given matrix size, field-of-view (FoV), and spectral bandwidth, the radius of ECCENTRIC circles can be chosen to ensure that, even without temporal interleaving, the limits of gradient hardware’s slew rate and amplitude are not exceeded. As detailed below, ECCENTRIC sampling fulfills better the random undersampling required by CS compared to echo-planar (Hu et al., 2008, 2010; Iqbal et al., 2016; Kampf et al., 2010; Otazo et al., 2009; Santos-Díaz & Noseworthy, 2019), spiral (Chatnuntawech et al., 2015), and radial (Saucedo et al., 2021) trajectories.

In Figure 2, a comparison is made between ECCENTRIC, uniform distributed circles trajectory, concentric circles, and rosette sampling. The trajectory and sampling density in the k-space for each pattern and acceleration factor highlight the differences in sampling distribution. While rosette and concentric circle trajectories provide high sampling density at the center of k-space, uniformly distributed circles exhibit a flat and less optimal sampling density in terms of SNR. Accurate reconstruction benefits from sampling the center of k-space, which contains data with the highest SNR. The density distribution of ECCENTRIC lies between that of rosette and concentric circles and uniform distribution. It features a high-density singularity at the k-space center which gradually decreases towards the periphery of k-space.

Fig. 2.

Comparative analysis of circular k-space encodings. Top left, k-space trajectories for ECCENTRIC, uniform distributed circles, concentric circles, and rosette trajectories for a 64×64 encoding matrix. Red dots indicate the circle center positions. The acceleration factors AF = 1,2,3 correspond to ECCENTRIC and uniform distributed circles trajectories with 202, 101, and 67 circles respectively; 31, 16, and 11 concentric circles; 101, 51, and 34 Rosette circles. Top right, the point spread function (PSF) calculated for each trajectory and acceleration on a log-scale highlight the presence of incoherent and coherent aliasing patterns. Bottom, the sampling density for the same trajectories and AFs, represented in the 2D k-space (left) and along a radial projection (right).

Fig. 2.

Comparative analysis of circular k-space encodings. Top left, k-space trajectories for ECCENTRIC, uniform distributed circles, concentric circles, and rosette trajectories for a 64×64 encoding matrix. Red dots indicate the circle center positions. The acceleration factors AF = 1,2,3 correspond to ECCENTRIC and uniform distributed circles trajectories with 202, 101, and 67 circles respectively; 31, 16, and 11 concentric circles; 101, 51, and 34 Rosette circles. Top right, the point spread function (PSF) calculated for each trajectory and acceleration on a log-scale highlight the presence of incoherent and coherent aliasing patterns. Bottom, the sampling density for the same trajectories and AFs, represented in the 2D k-space (left) and along a radial projection (right).

Close modal

The point spread function (PSF) simulations in Figure 2 illustrate that ECCENTRIC is inherently suited for the random undersampling necessary to achieve optimal CS performance (Michael et al., 2007). The PSF reflects the interference between voxels in image space resulting from undersampling. Simulations reveal an incoherent pattern for PSF of ECCENTRIC due to the pseudo random k-space sampling, and the PSF pattern spreads with the increasing acceleration factor but conserve the pseudo-random behavior with undersampling (Fig. 2). In comparison, uniform distributed circles, concentric circles, and rosette trajectories have more compact PSFs for fully sampled acquisitions and their PSFs exhibit coherent patterns when undersampling is applied, which is less favorable for CS acceleration. The PSF was computed on a 64×64 matrix and obtained from a single point source (Mareci & Brooker, 1991) that was encoded in k-space and then reconstructed with Non-uniform Fourier transform with Voronoi’s partition density compensation (Rasche et al., 1999).

To extend ECCENTRIC to 3D k-space sampling, a stack of ECCENTRIC is employed with circles randomly placed in the kx- ky planes, while kz is encoded using Cartesian phase-encoding (Fig. 1D). The 3D k-space can be covered using spherical or ellipsoid coverage, where the in-plane k-space boundary is defined as kx,ymax=n2FoV1(kz/kzmax)2, with FoV representing the FoV size and n the spatial resolution. The spherical k-space coverage yields an additional acceleration factor of 1.5 compared to cylindrical k-space coverage. To achieve complete sampling in a single kx- ky plane, the number of needed ECCENTRIC circles can be derived similar to rosette encoding that requires πn2 circles (Schirda et al., 2009). Expanding from the number of points of a fully sampled rosette trajectory to ellipsoidal coverage, the total number of ECCENTRIC circles required for complete sampling of a single partition of the stack is πnkx,ymax2R. To achieve circle encoding with off-center position (rc,ϕc), a brief gradient ramp is used to gain an initial momentum (kx,ky) position and the necessary velocity. This process is done at the same time as the slab excitation rewinder overlapped by z-phase encoding and does not increase the echo time, as shown in Figure 1E. In implementing CS acceleration, the total number of ECCENTRIC circles Nc is reduced uniformly across the stacks by a factor of AF. Since each circle pattern for every partition of the ECCENTRIC stack is randomly drawn, this results in sparse and random sampling across all three dimensions of the k-space.

Due to the non-uniformity and sparsity of the sampling, a specific model is necessary to reconstruct 4D (k,t) data of ECCENTRIC into image-frequency space. In previous studies (Klauser et al., 2019, 2021, 2022), we demonstrated the effectiveness of CS-SENSE-LR model that combines partial-separability (or low-rank) with Total-Generalized-Variation (TGV) constraint for reconstructing Cartesian k-space data acquired with random undersampling, leading to improved SNR. Here, we extended the CS-SENSE-LR approach to incorporate non-uniform Fourier sampling necessary for reconstructing ECCENTRIC data. Defining the discrete MRSI data in image space to be ρ as an Nr by T array (with Nr the number of spatial points and T the number of sampling time points), the low-rank hypothesis on the magnetization assumes that the MRSI data can be separated into a small number of spatial and temporal components:

(1)

where U is a Nr by K array and V a K by T array, with K the rank of the low-rank model. These components are retrieved by CS-SENSE-LR reconstruction solving the inverse problem

(2)

where s the measured data, the non-uniform Fourier transform (NUFT) encoding operator, C the coil sensitivity operator, the B0 frequency shift operator, and L represent the lipid signal (Nr by T array) from skull that is reconstructed simultaneously with brain metabolite U and V but on a separate spatial support. W is a weighting operator of a Hamming window shape, and decreasing with the distance to the center of the k-space (Ban et al., 2019; Klauser et al., 2021). The NUFT encoding operator of ECCENTRIC is a discrete non-uniform Fourier transform of type 1:

(3)

with ri are the uniform image space coordinates and kjk-space sampling-point coordinates located on the 3D ECCENTRIC circles.

TGV2 is the total generalized variation cost function with λ the regularization parameter (Knoll, Bredies, et al., 2011). The regularization parameter used in the reconstruction was adjusted to λ=3×104 by gradually increasing it from a low value until the noise-like artifacts in the metabolite maps disappeared (Klauser et al., 2022; Knoll, Bredies, et al., 2011). The reconstruction rank, K, was determined qualitatively as the minimum number of components that contain some signal distinguishable from noise. For the 3D ECCENTRIC reconstruction, K was specifically set to 40. Additional information regarding the determination of K and an illustration of its impact on the results are available in the Supplementary Material and depicted in Figures S9–S11.

The contamination of U and V by skull-lipid signal is prevented by filtering of the gradient descent during the reconstruction (Eq. 2). Lipid signal is removed from each step of the gradient descent by applying the operator (1) with the lipid subspace projection computed from the estimated lipid signal at the skull L (Klauser et al., 2019). The reconstruction algorithm for U and V, along with the detailed utilization of the lipid suppression operator (1), is further described in the Supplementary Material, accompanied by pseudocode for clarity.

3.1 ECCENTRIC FID-MRSI acquisition parameters

1H-FID-MRSI (Bogner et al., 2012; Henning et al., 2009) acquisition was implemented with 3D spherical stack-of-ECCENTRIC sampling as depicted in (Fig. 1E) on a 7T scanner (MAGNETOM Terra, Siemens Healthcare, Erlangen, Germany) running VE12U SP1 software and equipped with NOVA head coils (32Rx/1Tx and 32Rx/8Tx). The echo-time (TE) was set to the minimum possible: 0.9 ms with a 27 degree excitation flip-angle (FA) and 275 ms repetition-time (TR). A slab-selective excitation was performed with a Shinnar-LeRoux optimized pulse (Klauser et al., 2021; Pauly et al., 1991) with 6.5 kHz bandwidth and was preceded by four-pulses WET water suppression scheme (Klauser et al., 2021; Ogg et al., 1994) (Fig. 1). The FoV was 220×220×105 mm3 (A-P/R-L/H-F) with 85 mm-thick excited slab. A voxel size of 3.4×3.4×3.4 mm3 (40.5 μl) was realized with a 64×64×31 matrix. The ECCENTRIC circles radius R was set to 1/8nFoV which corresponds to a diameter that encompasses a quarter of the width of the k-space, with n being the square matrix size. The radius R was selected to maximize the number of sampled points per circle, thereby optimizing SSE acceleration, while ensuring not to exceed the gradient system limits for the desired spectral bandwidth. With R=1/8nFoV, ECCENTRIC enables a spectral bandwidth of 2,280 Hz without the need for temporal interleaving for in-plane FoV = 220 x 220 mm2 and 64×64 matrix. The effect of circle radius on the SNR and the quality of metabolic maps was investigated in Supplementary Figures S14–S16. With this radius, ECCENTRIC circles cover 20 points in k-space, inherently providing an SSE acceleration of 20 without undersampling. The FID was sampled with 500 time-points which corresponds to the number of revolutions on each ECCENTRIC circle, and resulted in a total FID duration of 220 ms. To obtain the fully sampled (AF = 1) spherical 3D stack-of-ECCENTRIC with these parameters, a total number of Nc=4,072 circles is required, which corresponds to 18 min 40 sec acquisition time (TA). For accelerated acquisitions, we decreased the number of circles to Nc/AF, with TA being shortened proportionally. For instance, with the same encoding parameters, AF = 2 needs Nc=2,036 in 9 min 20 sec, AF = 3 needs Nc=1,357 in 6 min 16 sec, AF = 4 needs Nc=1,018 in 4 min 40 sec, and so on.

A rapid calibration scan of water reference data was performed by turning off water suppression and using the same FoV, FA slab excitation, TR, FID duration, and spectral bandwidth, but with rosette trajectory sampling at lower resolution (23×23×19) in 1 min 16 sec.

The B0 shimming of the 85 mm thick whole-brain slab was performed using the manufacturer methods that adjusted the shim currents over 12 spherical harmonics coils: three 1st order, five 2nd order, and four 3rd order. The global linewidth of the water over the entire 85 mm slab was between 25–42 Hz across all subjects. In the majority of the subjects the global water linewidth was between 30–35 Hz. Adjustment of the B1+ transmit and water suppression was subsequently performed with manufacturer methods. The entire adjustment procedure took between 1–2 min for every subject.

3.2 Reconstruction of ECCENTRIC FID-MRSI metabolic images

The rapid water reference data were used to compute the coil sensitivity maps using ESPIRiT (Uecker et al., 2014) (C operator in Eq. 2) and to estimate a ΔB0 field map with multiple signal classification algorithm (MUSIC) (Gruber & Hayes, 1997). The field correction operator in Equation 2 was then determined by =ei2πtγΔB0, where γΔB0 is the spatial frequency shift caused by the field inhomogeneity map (in Hz). To reconstruct 3D ECCENTRIC FID-MRSI data and obtain the metabolic images, we employed a comprehensive pipeline that included: 1) water removal using the HSVD method (Barkhuijsen et al., 1987) for each coil channel (Klauser et al., 2019), 2) determination of the ΔB0 field map and the coil sensitivity maps from the rapid water reference data, 3) CS-SENSE-LR reconstruction model from Equation 2, which includes simultaneous suppression of scalp lipid signals, and 4) spectral fitting by LCModel software (Provencher, 1993) with the reconstructed rapid water reference data serving as the normative signal. Because FID gradient-echo excitation does not refocus chemical shift evolution during echo-time the spectra need first order phase correction, which was performed by backward linear prediction of the evolution (Nassirpour, Chang, & Henning, 2018a). A metabolite basis obtained by quantum mechanics simulations in GAMMA (Smith et al., 1994) was utilized to fit and quantify 21 metabolites: phosphocholine (PCh), glycerophosphocholine (GPC), creatine (Cr), phosphocreatine (PCr), gamma-aminobutyric acid (GABA), glutamate (Glu), glutamine (Gln), glycine (Gly), glutathione (GSH), myo-inositol (Ins), N-acetylaspartate (NAA), N-acetyl aspartylglutamate (NAAG), scyllo-inositol (Sci), lactate (Lac), threonine (Thr), beta-glucose (bGlu), alanine (Ala), aspartate (Asp), ascorbate (Asc), serine (Ser), and taurine (Tau). Phosphorylcholine and glycerophosphorylcholine were combined into total choline-containing compounds (Cho), while creatine and phosphocreatine were combined into total creatine (tCre). Concentration maps were then generated for the metabolites included in the simulated basis.

The water reference signal was used as quantification reference by LCModel, and the resulting concentration estimates were expressed in institutional units (I.U.). This allowed for comparisons of metabolite levels across both subjects and different metabolites. The ultra-short TE used in the ECCENTRIC MRSI data acquisition meant that T2 relaxation correction was unnecessary for both metabolite and water signals. As a result of employing a short TR with Ernst flip angle, metabolite maps may contain T1-weighted contrast. Correcting for this would necessitate measuring B1+ field and incorporating prior knowledge of metabolite T1. The results of the LCModel fitting for each voxel were further used to generate spatial maps of the concentration of each metabolite. To assess the quality of the MRSI data and the goodness of fit, quality control maps of Cramer-Rao lower bounds (CRLB), line-width (FWHM), and SNR were generated from the LCModel fitting.

3.3 ECCENTRIC FID-MRSI in high-resolution phantom

Experimental performance of ECCENTRIC sampling was first tested on a high-resolution structural-metabolic phantom. We used a custom-made phantom with geometry similar to Derenzo molecular imaging phantom (Derenzo et al., 1977) containing 5 sets of tubes with diameters of 2, 4, 6, 8 and 10 mm as shown in Figure 3. Each set contained 6 tubes of identical diameter separated by a distance equal to twice the inner diameter positioned in a triangular configuration. In every set, the six tubes were filled with metabolite solutions containing 10 mM of creatine. Magnevist (Gd-DTPA) was added (1 mL/L) in each tube to shorten T1 and create T1-weighted contrast for structural MRI. The whole tube structure was inserted in a large cylindrical container (13.33 cm inner diameter) which was filled with 10 mM NaCl solution. Further details of phantom manufacturing and chemical composition are mentioned in Klauser et al. (2021).

Fig. 3.

ECCENTRIC imaging of water and metabolites in the high-resolution structural-metabolic phantom. ECCENTRIC performance was tested for spatial resolutions of 4.6, 3.4, 2.8, 2.0 mm and acceleration factors between 1–12. Top, examples of water and creatine images are shown for all 4 resolutions and 4 acceleration (AF: 1,4,8,12). Bottom, SSIM and correlation factors for each resolution and acceleration are calculated considering as ground truth the fully sampled image (AF = 1).

Fig. 3.

ECCENTRIC imaging of water and metabolites in the high-resolution structural-metabolic phantom. ECCENTRIC performance was tested for spatial resolutions of 4.6, 3.4, 2.8, 2.0 mm and acceleration factors between 1–12. Top, examples of water and creatine images are shown for all 4 resolutions and 4 acceleration (AF: 1,4,8,12). Bottom, SSIM and correlation factors for each resolution and acceleration are calculated considering as ground truth the fully sampled image (AF = 1).

Close modal

Due to the phantom’s geometric structure being present only in the axial section, we opted for a 2D ECCENTRIC acquisition. The sampling scheme for 2D ECCENTRIC is identical to the central k-space partition used in 3D ECCENTRIC. The 2D ECCENTRIC acquisition maintained the same RF-pulse and FA but required slightly longer TE to 1.15 ms, and the TR was set to 450 ms to accommodate the longer T1 relaxation times in the phantom. The FID was measured with a spectral bandwidth of 2,000 Hz over 350 ms, and successive acquisitions were performed with increased in-plane resolution. The circle radius (R) was set to n8FoV, n8FoV, n9FoV, and n10FoV for 4.6, 3.4, 2.8, and 2.0 mm in-plane resolutions, respectively, to avoid temporal interleaving for any spatial resolution.

In addition to metabolite imaging, we conducted water imaging of the structural phantom at identical spatial resolutions to more comprehensively evaluate the spatial encoding performance of ECCENTRIC. To accomplish this, we employed the 2D ECCENTRIC sequence without water suppression, utilizing a short TR of 100 ms and an FA of 40 degrees. This choice was made to maximize the T1-weighted (T1w) contrast of the tubes within the cylindrical phantom. Subsequently, the first point of the acquired timeseries was reconstructed to generate the T1-weighted water image. Both metabolite and water data were acquired with fully sampled ECCENTRIC. To investigate accelerations, the fully sampled ECCENTRIC data were retrospectively undersampled for acceleration factors (AF) between 212.

The effect of the acceleration on water and metabolite imaging was evaluated by analyzing the structural similarity index (SSIM) and correlation coefficient for all voxels inside the phantom with respect to the fully sampled data (Fig. 3).

3.4 ECCENTRIC FID-MRSI in healthy volunteers

Five healthy volunteers were scanned at Athinoula A. Martinos Center For Biomedical Imaging for this study. The protocol was approved by the institutional ethics committee, and written informed consent was given by all subjects before participation. The 3D ECCENTRIC FID-MRSI sequence described above was acquired with voxel size of 3.4 mm isotropic at AF = 1,2,3 and 4 successively. In two volunteers, the performance of 3D ECCENTRIC FID-MRSI was also tested at ultra-high resolution with voxel size of 2.5 mm isotropic (matrix 88×88×43, AF = 4, TA = 10 min 26 sec) and compared to 3.4 mm isotropic (matrix 64×64×31, AF = 2, TA = 9 min 20 sec). Our objective was to determine the feasibility of achieving a metabolic imaging protocol that delivers close to 3 mm isotropic whole-brain coverage in under 10 min using ECCENTRIC.

All volunteers were scanned with a T1-weighted anatomical MP2RAGE sequence (Marques et al., 2010) (1 mm isotropic, 4,300 ms TR, 840 ms and 2,370 ms TI) for positioning of the MRSI FoV and for the generation of skull-masks that are needed for the lipid removal during the reconstruction and to exclude voxels located outside the head volume.

3.5 Quantitative analysis

For quantitative analysis of 3D ECCENTRIC FID-MRSI, the metabolite concentrations (I.U.) were analyzed in each brain lobe and tissue type. This involved segmenting MP2RAGE images into gray matter, white matter, and cerebrospinal fluid using Freesurfer version 7.1.1 software (Fischl et al., 2002). Cerebral lobes were then identified utilizing a standard atlas, and a general linear model was employed to estimate metabolite concentrations within each atlas-defined structure (Klauser et al., 2022).

3.6 Reproducibility analysis

The reproducibility of metabolite maps measured by 3D ECCENTRIC FID-MRSI were assessed by repeated imaging in four healthy volunteers. All scans were conducted sequentially without repositioning the volunteer. For the reproducibility analysis, three data sets with AF=3 in each volunteer were compared. One data set was acquired with AF=3, and the other two datasets were obtained by retrospective undersampling to AF=3 the data acquired with AF=1 and AF=2. Coefficients-of-variation (COV) were computed for individual anatomical regions from the three data sets. Both inter-measurement and inter-subject COVs were calculated and then averaged across subjects.

4.1 ECCENTRIC imaging in high-resolution phantom

In the series of water imaging experiments, ECCENTRIC can resolve the structural details of the phantom up to the resolution targeted by the imaging protocol as can be seen in Figure 3.

For water images, no visible difference in image quality can be seen for retrospective accelerations factors up to AF = 4, minor changes can be detected for AF between 4–8, and moderate loss of details for AF between 8–12 when compared to the fully sampled acquisition (AF = 1). Considering AF = 1 as ground truth, quantitative analysis reveals that SSIM 0.99 across all resolutions for accelerations up to AF = 4, and SSIM decreases to 0.97 for the highest acceleration and resolution tested. Similarly, correlation factors larger than 0.99 are observed up AF = 4, which decrease to 0.95 for the lowest resolution and largest acceleration factor. Comparing the different spatial resolutions, the higher CS accelerations show better performance for higher resolution images.

In the series of metabolite imaging experiments, ECCENTRIC was used to image the creatine metabolite present in the tubes with the same resolutions and acceleration factors as in the water imaging (Fig. 3). These results of these experiments show that: 1) metabolite maps exhibit comparable quality for AF between 1–4, 2) for AF>4 there is reduction in image details and an elevation of the noise level. Considering AF = 1 as ground truth, across the entire series of measurements SSIM range between 0.75–0.89, and correlation factors between 0.79–0.96. Unlike the water imaging results, the increasing acceleration does not yield higher SSIM and correlation factors as the spatial resolution increases. This discrepancy is likely attributed to the much lower (103104 less) SNR of metabolites in comparison to water, which becomes critical for the smallest voxel size. In particular, we note that for isotropic voxel size of 3.4 mm and for acceleration factors up to 4 we obtained the highest SSIM and correlation factors for metabolic imaging.

4.2 ECCENTRIC FID-MRSI in healthy volunteers

Examples of metabolic images for seven metabolites obtained with retrospective AF=14 are shown in Figure 4. Very similar structural details and tissue contrast of metabolic images are obtained for all accelerations compared to the fully sampled data. This is visible also by inspecting spectra that show the same metabolic profile across acceleration factors (AF=14). The CS accelerations (AF=2,3,4) were achieved by retrospectively undersampling the fully acquired data (AF=1). The purpose of this was to focus the analysis on the effects of CS acceleration, while avoiding any image differences that could be caused by head motion during different acquisitions. To illustrate the effect of each component of the CS-SENSE-LR reconstruction, we modified the model to isolate and evaluate each feature independently. The results are presented in Supplementary Material Section II.B and Figure S8, and are consistent with previously published data obtained using similar reconstruction models for Cartesian CS FID-MRSI (see supplementary material in Klauser et al. (2021)). To validate the low-resolution rapid water reference measurement described in Section 3.1 and used for the reconstruction and quantification, we compared it in Supplementary Figure S12 with a water 3D ECCENTRIC FID-MRSI reference acquisition, which matched the spatial resolution of the metabolite measurement.

Fig. 4.

3D ECCENTRIC FID-MRSI metabolic images of human brain acquired in a healthy volunteer with 3.4 mm isotropic voxel size and CS acceleration factors AF = 1–4. Top, metabolite maps of seven relevant brain metabolites (NAA, tCre, Cho, Glu, GABA, GSH, and NAAG) are shown for all acceleration factors (AF). Spectra from three brain locations indicated by red arrows on the anatomical image. At the bottom, the left plot displays the correlation coefficients between accelerated images (AF=2,3,4) and fully sampled images (AF=1), while the right plot shows the LCModel quantification error (CRLB), linewidth (FWHM), and SNR.

Fig. 4.

3D ECCENTRIC FID-MRSI metabolic images of human brain acquired in a healthy volunteer with 3.4 mm isotropic voxel size and CS acceleration factors AF = 1–4. Top, metabolite maps of seven relevant brain metabolites (NAA, tCre, Cho, Glu, GABA, GSH, and NAAG) are shown for all acceleration factors (AF). Spectra from three brain locations indicated by red arrows on the anatomical image. At the bottom, the left plot displays the correlation coefficients between accelerated images (AF=2,3,4) and fully sampled images (AF=1), while the right plot shows the LCModel quantification error (CRLB), linewidth (FWHM), and SNR.

Close modal

Visual inspection of metabolic images reveal that: 1) tCre, Glu, and GABA have larger signal in gray matter than white matter, 2) NAA has more signal in gray than white matter, but with lower gray-white matter contrast compared to tCre, Glu, and GABA, 3) Cho has higher signal in frontal white matter than gray matter, and 4) NAAG has the largest contrast from all metabolites, with much larger signal in white matter compared to gray matter. Metabolic images obtained with AF=1 and AF=2 are largely identical. Minor blurring of fine structural details starts to become noticeable for AF3, however adequate delineation of gray-white matter folding is maintained up to AF=4. Additionally, the performance of ECCENTRIC to reveal brain structural details was probed also by water imaging in four healthy volunteers. Brain water imaging by ECCENTRIC shows comparable performance for AF between 1–10 (Supplementary Fig. S13), similar to the phantom results.

Quantitative image analysis shows that the correlation between the accelerated and fully sampled metabolic images is high (R > 0.7) for metabolites that have a high SNR (>10) such as NAA, Cho, tCre, Glu, and Ins, while metabolites of lower SNR such as Gln, GABA, GSH, and NAAG exhibit lower correlations (R = 0.40.7). The error (CRLB) of spectral fitting is below 20%, which indicates very high goodness-of-fit by LCModel software. The CRLB does not degrade with the acceleration factor, except for NAAG and GABA, although even in this case it does not exceed the 20% limit. The SNR shows only a minor decrease between AF=1 (SNR = 17) and AF=4 (SNR = 15), while the linewidth does not degrade with acceleration.

4.3 Quantitative analysis of ECCENTRIC metabolic imaging

Table 1 presents brain regional concentrations of nine metabolites quantified using water signal as reference and expressed in institutional units (I.U.). The concentrations were calculated in the gray and white matter of the five major brain lobes across the five healthy volunteers. Our results indicate that: 1) six metabolites have higher concentrations in gray-matter compared to white matter (GM/WM = 1.19 tCre, 1.12 NAA, 1.2 Glu, 1.34 Gln, 1.15 GABA, 1.11 GSH); 2) two metabolites have higher concentrations in white-matter compared to gray-matter (GM/WM = 0.96 Cho, 0.47 NAAG); and 3) one metabolite has region-dependent gray/white-matter ratio (GM/WM = 1.17–0.87 Ins). The largest gray-white matter contrast is exhibited by NAAG due to its specific compartmentalization in white matter.

Table 1.

Metabolite concentrations (I.U.) and quantification error (Cramér-Rao lower bound, CRLB %) in each brain lobe and tissue type.

Mean across volunteersFrontalLimbicParietalOccipitalTemporalUsable voxels
(Standard deviation)WMGMWMGMWMGMWMGMWMGMMean % (std)
tCre [I.U.] 3.34 (0.34) 3.84 (0.04) 3.22 (0.35) 4.46 (0.28) 3.30 (0.28) 3.95 (0.28) 3.31 (0.30) 3.39 (0.19) 3.09 (0.25) 3.81 (0.19)  
tCre CRLB [%] 3.25 (0.24) 3.54 (0.41) 3.38 (0.31) 3.18 (0.30) 3.21 (0.33) 3.26 (0.26) 3.45 (0.62) 3.64 (0.62) 3.42 (0.37) 3.33 (0.26) 73.3 (3.3) 
NAA [I.U.] 4.16 (0.98) 4.51 (0.66) 4.07 (1.01) 5.38 (0.90) 4.31 (0.96) 4.84 (0.88) 4.33 (0.98) 4.18 (0.85) 3.91 (0.84) 4.35 (0.73)  
NAA CRLB [%] 3.13 (0.34) 3.55 (0.64) 3.26 (0.33) 3.07 (0.36) 2.86 (0.26) 3.05 (0.37) 3.30 (0.54) 3.63 (0.64) 3.32 (0.39) 3.32 (0.34) 73.0 (3.5) 
Ins [I.U.] 3.49 (0.52) 3.51 (0.35) 3.65 (0.60) 4.28 (0.48) 3.73 (0.66) 3.58 (0.29) 3.74 (0.65) 3.27 (0.57) 3.56 (0.65) 3.39 (0.51)  
Ins CRLB [%] 5.33 (0.64) 6.04 (0.94) 5.29 (0.52) 5.36 (0.42) 5.16 (0.42) 5.63 (0.52) 5.38 (0.48) 5.84 (0.50) 5.34 (0.33) 5.68 (0.40) 73.0 (3.5) 
GPC+PCh [I.U.] 1.03 (0.10) 0.93 (0.05) 1.10 (0.10) 1.24 (0.08) 1.06 (0.11) 0.95 (0.09) 0.94 (0.12) 0.79 (0.06) 0.99 (0.07) 0.98 (0.12)  
GPC+PCh CRLB [%] 3.63 (0.34) 4.24 (0.59) 3.46 (0.31) 3.56 (0.27) 3.56 (0.29) 3.97 (0.33) 4.13 (0.57) 4.59 (0.64) 3.68 (0.29) 3.94 (0.25) 73.5 (3.3) 
Glu [I.U.] 3.86 (0.53) 4.50 (0.29) 3.72 (0.49) 5.24 (0.46) 3.86 (0.39) 4.61 (0.39) 3.80 (0.36) 3.82 (0.38) 3.50 (0.35) 4.29 (0.44)  
Glu CRLB [%] 4.51 (0.51) 5.01 (0.85) 4.72 (0.59) 4.37 (0.47) 4.31 (0.53) 4.48 (0.55) 4.82 (1.14) 5.22 (1.32) 4.80 (0.74) 4.71 (0.64) 72.8 (3.8) 
Gln [I.U.] 0.89 (0.06) 1.24 (0.25) 0.83 (0.06) 1.33 (0.16) 0.80 (0.16) 1.08 (0.26) 0.87 (0.22) 0.91 (0.21) 0.80 (0.09) 1.07 (0.22)  
Gln CRLB [%] 15.93 (2.45) 14.81 (2.22) 17.72 (2.68) 14.38 (2.48) 17.92 (4.78) 16.22 (3.24) 18.99 (5.14) 18.77 (4.11) 18.30 (2.95) 16.45 (2.60) 56.3 (4.6) 
GABA [I.U.] 1.34 (0.09) 1.48 (0.29) 1.34 (0.10) 1.79 (0.37) 1.37 (0.14) 1.58 (0.30) 1.33 (0.18) 1.37 (0.18) 1.21 (0.16) 1.39 (0.32)  
GABA CRLB [%] 8.68 (1.10) 9.61 (1.51) 8.86 (1.50) 8.52 (1.74) 8.54 (2.08) 8.78 (1.76) 9.48 (2.34) 9.90 (2.22) 9.60 (2.16) 9.52 (2.09) 68.3 (1.5) 
GSH [I.U.] 1.07 (0.24) 1.22 (0.05) 1.11 (0.26) 1.45 (0.20) 1.10 (0.20) 1.17 (0.07) 1.05 (0.18) 1.00 (0.09) 1.02 (0.17) 1.14 (0.12)  
GSH CRLB [%] 8.20 (0.88) 8.77 (1.15) 8.29 (0.93) 7.96 (0.79) 8.04 (1.00) 8.43 (0.87) 9.12 (2.01) 9.80 (1.90) 8.65 (1.23) 8.81 (1.17) 71.5 (3.1) 
NAAG [I.U.] 0.82 (0.14) 0.39 (0.12) 0.90 (0.13) 0.49 (0.17) 0.96 (0.17) 0.34 (0.13) 0.78 (0.16) 0.41 (0.12) 0.76 (0.11) 0.35 (0.10)  
NAAG CRLB [%] 14.11 (4.10) 19.02 (5.07) 12.43 (3.87) 17.35 (6.07) 12.01 (3.14) 18.03 (5.15) 15.51 (5.08) 19.40 (6.62) 15.36 (5.01) 20.13 (6.40) 45.3 (11.6) 
SNR 24.64 (4.41) 23.67 (3.84) 22.92 (4.50) 24.53 (4.02) 25.64 (4.82) 24.73 (4.17) 22.48 (6.13) 21.32 (5.56) 22.07 (4.23) 22.40 (3.37)  
FWHM [Hz] 11.43 (0.91) 12.09 (0.77) 11.28 (1.15) 11.13 (1.13) 10.21 (0.79) 11.02 (0.84) 11.64 (0.91) 12.33 (1.04) 12.26 (1.23) 12.38 (1.22)  
Mean across volunteersFrontalLimbicParietalOccipitalTemporalUsable voxels
(Standard deviation)WMGMWMGMWMGMWMGMWMGMMean % (std)
tCre [I.U.] 3.34 (0.34) 3.84 (0.04) 3.22 (0.35) 4.46 (0.28) 3.30 (0.28) 3.95 (0.28) 3.31 (0.30) 3.39 (0.19) 3.09 (0.25) 3.81 (0.19)  
tCre CRLB [%] 3.25 (0.24) 3.54 (0.41) 3.38 (0.31) 3.18 (0.30) 3.21 (0.33) 3.26 (0.26) 3.45 (0.62) 3.64 (0.62) 3.42 (0.37) 3.33 (0.26) 73.3 (3.3) 
NAA [I.U.] 4.16 (0.98) 4.51 (0.66) 4.07 (1.01) 5.38 (0.90) 4.31 (0.96) 4.84 (0.88) 4.33 (0.98) 4.18 (0.85) 3.91 (0.84) 4.35 (0.73)  
NAA CRLB [%] 3.13 (0.34) 3.55 (0.64) 3.26 (0.33) 3.07 (0.36) 2.86 (0.26) 3.05 (0.37) 3.30 (0.54) 3.63 (0.64) 3.32 (0.39) 3.32 (0.34) 73.0 (3.5) 
Ins [I.U.] 3.49 (0.52) 3.51 (0.35) 3.65 (0.60) 4.28 (0.48) 3.73 (0.66) 3.58 (0.29) 3.74 (0.65) 3.27 (0.57) 3.56 (0.65) 3.39 (0.51)  
Ins CRLB [%] 5.33 (0.64) 6.04 (0.94) 5.29 (0.52) 5.36 (0.42) 5.16 (0.42) 5.63 (0.52) 5.38 (0.48) 5.84 (0.50) 5.34 (0.33) 5.68 (0.40) 73.0 (3.5) 
GPC+PCh [I.U.] 1.03 (0.10) 0.93 (0.05) 1.10 (0.10) 1.24 (0.08) 1.06 (0.11) 0.95 (0.09) 0.94 (0.12) 0.79 (0.06) 0.99 (0.07) 0.98 (0.12)  
GPC+PCh CRLB [%] 3.63 (0.34) 4.24 (0.59) 3.46 (0.31) 3.56 (0.27) 3.56 (0.29) 3.97 (0.33) 4.13 (0.57) 4.59 (0.64) 3.68 (0.29) 3.94 (0.25) 73.5 (3.3) 
Glu [I.U.] 3.86 (0.53) 4.50 (0.29) 3.72 (0.49) 5.24 (0.46) 3.86 (0.39) 4.61 (0.39) 3.80 (0.36) 3.82 (0.38) 3.50 (0.35) 4.29 (0.44)  
Glu CRLB [%] 4.51 (0.51) 5.01 (0.85) 4.72 (0.59) 4.37 (0.47) 4.31 (0.53) 4.48 (0.55) 4.82 (1.14) 5.22 (1.32) 4.80 (0.74) 4.71 (0.64) 72.8 (3.8) 
Gln [I.U.] 0.89 (0.06) 1.24 (0.25) 0.83 (0.06) 1.33 (0.16) 0.80 (0.16) 1.08 (0.26) 0.87 (0.22) 0.91 (0.21) 0.80 (0.09) 1.07 (0.22)  
Gln CRLB [%] 15.93 (2.45) 14.81 (2.22) 17.72 (2.68) 14.38 (2.48) 17.92 (4.78) 16.22 (3.24) 18.99 (5.14) 18.77 (4.11) 18.30 (2.95) 16.45 (2.60) 56.3 (4.6) 
GABA [I.U.] 1.34 (0.09) 1.48 (0.29) 1.34 (0.10) 1.79 (0.37) 1.37 (0.14) 1.58 (0.30) 1.33 (0.18) 1.37 (0.18) 1.21 (0.16) 1.39 (0.32)  
GABA CRLB [%] 8.68 (1.10) 9.61 (1.51) 8.86 (1.50) 8.52 (1.74) 8.54 (2.08) 8.78 (1.76) 9.48 (2.34) 9.90 (2.22) 9.60 (2.16) 9.52 (2.09) 68.3 (1.5) 
GSH [I.U.] 1.07 (0.24) 1.22 (0.05) 1.11 (0.26) 1.45 (0.20) 1.10 (0.20) 1.17 (0.07) 1.05 (0.18) 1.00 (0.09) 1.02 (0.17) 1.14 (0.12)  
GSH CRLB [%] 8.20 (0.88) 8.77 (1.15) 8.29 (0.93) 7.96 (0.79) 8.04 (1.00) 8.43 (0.87) 9.12 (2.01) 9.80 (1.90) 8.65 (1.23) 8.81 (1.17) 71.5 (3.1) 
NAAG [I.U.] 0.82 (0.14) 0.39 (0.12) 0.90 (0.13) 0.49 (0.17) 0.96 (0.17) 0.34 (0.13) 0.78 (0.16) 0.41 (0.12) 0.76 (0.11) 0.35 (0.10)  
NAAG CRLB [%] 14.11 (4.10) 19.02 (5.07) 12.43 (3.87) 17.35 (6.07) 12.01 (3.14) 18.03 (5.15) 15.51 (5.08) 19.40 (6.62) 15.36 (5.01) 20.13 (6.40) 45.3 (11.6) 
SNR 24.64 (4.41) 23.67 (3.84) 22.92 (4.50) 24.53 (4.02) 25.64 (4.82) 24.73 (4.17) 22.48 (6.13) 21.32 (5.56) 22.07 (4.23) 22.40 (3.37)  
FWHM [Hz] 11.43 (0.91) 12.09 (0.77) 11.28 (1.15) 11.13 (1.13) 10.21 (0.79) 11.02 (0.84) 11.64 (0.91) 12.33 (1.04) 12.26 (1.23) 12.38 (1.22)  

The two bottom rows present the SNR and FWHM values. The last column shows the percentage of voxels inside the brain and FoV that meet the criteria of good quality: CRLB <20%, FWHM <0.07ppm, SNR >5. The values are calculated as the average (standard deviation) across the healthy volunteers imaged by 3D ECCENTRCIC at 3.4 mm isotropic with AF=2 (9 min:20 sec acquisition time).

Quantitative parameters for the quality of MRSI data are also listed in Table 1, including the precision of metabolite quantification by the Cramer-Rao lower bounds (CRLB), the SNR, and spectral linewidth (FWHM). It is worth noting that the values of spectral SNR and fitting CRLB are influenced by our reconstruction method. The CS-SENSE-LR reconstruction incorporates a low-rank model, effectively reducing noise, thereby enhancing SNR and lowering CRLB values. Consequently, the SNR and CRLB metrics not only reflect the acquisition quality but also the effectiveness of the reconstruction process. Therefore, these values may vary from studies that do not employ similar reconstruction techniques. It can be seen that mean CRLB is below <20% for all the metabolites across the imaged whole-brain volume. In particular, mean CRLB is below <6% for the five metabolites with highest SNR (NAA, tCre, Cho, Glu, and Ins), between 8%10% for two metabolites (GABA and GSH) and between 14%20% for other two metabolites (Gln and NAAG). Across the brain, the mean SNR after the denoising reconstruction is larger than 20 and the mean linewidth is less than 12 Hz (0.04 ppm).

4.4 Reproducibility of ECCENTRIC metabolic imaging

Results from repeated measurements are shown in Figure 5 for Glu imaging. Due to high concentration of Glu in gray mater, Glu images have high gray-white matter contrast and show fine structural details of brain that can be used to visually assess the stability of the imaging with increasing AF. It can be seen that across all four scans in all four subjects the metabolite images appear visually similar. We note that with repeated measurements some anatomical differences may also be attributed to slight head motion. All metabolite maps, along with their respective CRLB, SNR, and FWHM maps for all four volunteers and AF, are presented in Supplementary Figures S1–S7.

Fig. 5.

Glutamate imaging at 3.4 mm isotropic voxel size in four healthy volunteers scanned with 3D ECCENTRIC FID-MRSI in four successive acquisitions with increasing accelerations AF = 1, 2, 3, and 4. Three slices are shown for each volunteer at each acceleration.

Fig. 5.

Glutamate imaging at 3.4 mm isotropic voxel size in four healthy volunteers scanned with 3D ECCENTRIC FID-MRSI in four successive acquisitions with increasing accelerations AF = 1, 2, 3, and 4. Three slices are shown for each volunteer at each acceleration.

Close modal

The inter-measurement COV for mapping metabolite concentrations across brain regions are presented in Table 2 and the inter-subject COV in Table 3. Inter-measurement COV smaller than 7% are observed for five metabolites (NAA, tCre, Ins, Cho, Glu) that are the most abundant in the brain. COV between 8%14% are obtained for Gln, GSH, and GABA. NAAG has higher COV in brain regions (gray matter) where its concentration is low.

Table 2.

The inter-measurement coefficient of variation (COV) for each metabolite determined in every lobe and tissue type for the 3D ECCENTRIC FID-MRSI acquired at 3.4 mm isotropic resolution in 6 min:16 sec (AF = 3).

Inter-measurement COV
FrontalLimbicParietalOccipitalTemporal
WMGMWMGMWMGMWMGMWMGM
NAA 0.06 0.03 0.06 0.05 0.06 0.05 0.05 0.07 0.06 0.06 
tCre 0.05 0.05 0.05 0.03 0.03 0.04 0.04 0.03 0.06 0.05 
Ins 0.05 0.04 0.07 0.06 0.05 0.05 0.04 0.06 0.06 0.07 
GPC+PCh 0.04 0.03 0.03 0.04 0.04 0.06 0.03 0.04 0.03 0.05 
Glu 0.05 0.03 0.05 0.05 0.07 0.07 0.07 0.07 0.06 0.07 
Gln 0.14 0.10 0.15 0.11 0.12 0.12 0.12 0.07 0.14 0.08 
GABA 0.07 0.11 0.05 0.07 0.09 0.12 0.05 0.11 0.06 0.11 
GSH 0.12 0.10 0.14 0.13 0.13 0.13 0.13 0.10 0.14 0.11 
NAAG 0.23 0.41 0.28 0.33 0.24 0.55 0.26 0.40 0.28 0.54 
Inter-measurement COV
FrontalLimbicParietalOccipitalTemporal
WMGMWMGMWMGMWMGMWMGM
NAA 0.06 0.03 0.06 0.05 0.06 0.05 0.05 0.07 0.06 0.06 
tCre 0.05 0.05 0.05 0.03 0.03 0.04 0.04 0.03 0.06 0.05 
Ins 0.05 0.04 0.07 0.06 0.05 0.05 0.04 0.06 0.06 0.07 
GPC+PCh 0.04 0.03 0.03 0.04 0.04 0.06 0.03 0.04 0.03 0.05 
Glu 0.05 0.03 0.05 0.05 0.07 0.07 0.07 0.07 0.06 0.07 
Gln 0.14 0.10 0.15 0.11 0.12 0.12 0.12 0.07 0.14 0.08 
GABA 0.07 0.11 0.05 0.07 0.09 0.12 0.05 0.11 0.06 0.11 
GSH 0.12 0.10 0.14 0.13 0.13 0.13 0.13 0.10 0.14 0.11 
NAAG 0.23 0.41 0.28 0.33 0.24 0.55 0.26 0.40 0.28 0.54 
Table 3.

The inter-subject coefficient of variation (COV) for each metabolite determined in every lobe and tissue type for the 3D ECCENTRIC FID-MRSI acquired at 3.4 mm isotropic resolution in 6 min:16 sec (AF = 3).

Inter-subject COV
FrontalLimbicParietalOccipitalTemporal
WMGMWMGMWMGMWMGMWMGM
NAA 0.21 0.15 0.23 0.17 0.23 0.17 0.24 0.23 0.23 0.22 
tCre 0.10 0.05 0.12 0.07 0.11 0.05 0.09 0.09 0.11 0.09 
Ins 0.18 0.15 0.22 0.17 0.22 0.14 0.21 0.26 0.24 0.19 
GPC+PCh 0.06 0.07 0.07 0.06 0.10 0.10 0.12 0.14 0.11 0.15 
Glu 0.19 0.13 0.20 0.16 0.20 0.15 0.18 0.18 0.18 0.20 
Gln 0.16 0.25 0.12 0.16 0.18 0.21 0.21 0.23 0.17 0.18 
GABA 0.37 0.33 0.39 0.38 0.36 0.36 0.38 0.39 0.37 0.40 
GSH 0.13 0.09 0.15 0.11 0.13 0.07 0.11 0.13 0.11 0.12 
NAAG 0.32 0.37 0.35 0.29 0.45 0.47 0.50 0.48 0.38 0.29 
Inter-subject COV
FrontalLimbicParietalOccipitalTemporal
WMGMWMGMWMGMWMGMWMGM
NAA 0.21 0.15 0.23 0.17 0.23 0.17 0.24 0.23 0.23 0.22 
tCre 0.10 0.05 0.12 0.07 0.11 0.05 0.09 0.09 0.11 0.09 
Ins 0.18 0.15 0.22 0.17 0.22 0.14 0.21 0.26 0.24 0.19 
GPC+PCh 0.06 0.07 0.07 0.06 0.10 0.10 0.12 0.14 0.11 0.15 
Glu 0.19 0.13 0.20 0.16 0.20 0.15 0.18 0.18 0.18 0.20 
Gln 0.16 0.25 0.12 0.16 0.18 0.21 0.21 0.23 0.17 0.18 
GABA 0.37 0.33 0.39 0.38 0.36 0.36 0.38 0.39 0.37 0.40 
GSH 0.13 0.09 0.15 0.11 0.13 0.07 0.11 0.13 0.11 0.12 
NAAG 0.32 0.37 0.35 0.29 0.45 0.47 0.50 0.48 0.38 0.29 

The results from Tables 2 and 3 show that 3D ECCENTRIC FID-MRSI had reproducible and stable performance in three repeat measurements. The inter-measurement COV exhibits a markedly lower value (2–4 times smaller) compared to the inter-subject COV. The former is primarily influenced by technical variability, whereas the latter reflects a combination of technical and biological variability. The quantification of the five main metabolites that have the highest SNR in brain MRSI (NAA, tCre, Cho, Ins, Glu) shows the lowest variability, with a slight increase in the case of less abundant metabolites (Gln, GABA, and GSH). The highest variability is noticed for NAAG outside of the fronto-parietal white matter due to its specific localization in this brain area. We note that in-vivo variability of metabolite quantification in repeat measurements is also influenced by patient motion and scanner stability in addition to 3D ECCENTRIC FID-MRSI, hence methods that reduce the effects of motion and field drift (Andronesi et al., 2021; Bogner et al., 2014) are likely to reduce variability.

4.5 Ultra-high resolution metabolic imaging of human brain using 3D ECCENTRIC FID-MRSI

We further explored the performance of 3D ECCENTRIC FID-MRSI for ultra-high resolution metabolic imaging in several healthy volunteers. Based on the high SNR of the 3.4 mm data after the denoising reconstruction, we expected that smaller voxels at higher resolution will still provide sufficient SNR for metabolite imaging. Figure 6 shows metabolic images obtained using 3D ECCENTRIC FID-MRSI with isotropic voxel size of 2.5 mm in two healthy volunteers.

Fig. 6.

Ultra-high resolution metabolic imaging acquired with 3D ECCENTRIC FID-MRSI at 2.5 mm isotropic voxel size (AF=4, TA = 10min:26s) in two healthy volunteers. The ultra-high resolution metabolic imaging is compared to 3D ECCENTRIC FID-MRSI at the typical voxel size of 3.4 mm isotropic (AF=2, TA = 9min:20s). Right, two spectra from both spatial resolution and corresponding to the red arrow location are shown. The blue line represents the MRSI data, and the red line is the fit performed by LCModel.

Fig. 6.

Ultra-high resolution metabolic imaging acquired with 3D ECCENTRIC FID-MRSI at 2.5 mm isotropic voxel size (AF=4, TA = 10min:26s) in two healthy volunteers. The ultra-high resolution metabolic imaging is compared to 3D ECCENTRIC FID-MRSI at the typical voxel size of 3.4 mm isotropic (AF=2, TA = 9min:20s). Right, two spectra from both spatial resolution and corresponding to the red arrow location are shown. The blue line represents the MRSI data, and the red line is the fit performed by LCModel.

Close modal

To achieve a feasible scan time, we used CS with AF=4. We demonstrated at the beginning of our work that AF=4 provides metabolic maps that are similar to those obtained through fully sampled 3D ECCENTRIC FID-MRSI. The AF=4 acceleration enabled the acquisition of 3D ECCENTRIC FID-MRSI at 2.5 mm isotropic resolution in 10 min:26 sec. For comparison, we also acquired the typical 3D ECCENTRIC FID-MRSI at 3.4 mm isotropic with AF=2 acceleration in 9 min:20 sec. As readily apparent by visual inspection, the metabolic maps at higher spatial resolution provide sharper delineation of the brain structure. No compromise is visible for signal-to-noise, contrast-to noise or other data quality metric at ultra-high resolution compared to typical resolution. We note that the acquisition time of 3D ECCENTRIC FID-MRSI at 2.5 mm with AF=4 is only slightly longer (1 min) than at 3.4 mm with AF=2. However, for the same acceleration factor the acquisition time of 3D ECCENTRIC FID-MRSI at 3.4 mm is 2.2 times faster than at 2.5 mm.

Our results here demonstrate that 3D ECCENTRIC FID-MRSI at 7T can simultaneously image an extended neurochemical panel of 10–14 metabolites with high SNR at high spatial resolution across whole-brain and with acquisition times that are feasible for human imaging. Particularly, we showed that the acquisition of fast non-Cartesian MRSI can be further accelerated up to 4-fold by CS, allowing metabolic imaging at 3.4 mm isotropic resolution in 4 min:40 sec and at 2.5 mm isotropic resolution in 10 min:26 sec, respectively. The CS-SENSE-LR reconstruction produces metabolic images with an effective voxel size identical to the nominal size (Klauser et al., 2021). This provides an advantage compared to other filtered reconstructions (Hangel et al., 2020; Hingerl et al., 2020) which increase the effective voxel volume. ECCENTRIC preserves the features of metabolic images across accelerations. When accelerated up to 4-fold by CS the loss of image quality is minor and the metabolic images effectively visualize the laminar structure of the brain similar to the unaccelerated (AF = 1) ground truth. Through the design of ECCENTRIC acquisition and denoising reconstruction, SNR is enhanced even at high accelerations. This enhancement is achieved by fully sampling the center of k-space and employing a low-rank reconstruction technique.

Here, we investigated the performance of 3D ECCENTRIC FID-MRSI for two applications scenarios: 1) high resolution metabolic imaging (3.4 mm in 4 min:40 sec) for studies that need to minimize imaging time, and 2) ultra-high resolution metabolic imaging (2.5 mm in 10 min:26 sec) for applications that need to probe brain neurochemistry with highest structural detail. Both of these protocols represent a significant advancement for non-invasive imaging of human brain metabolism by in vivo MRSI. Their performance level is comparable to other advanced MR imaging methods, such as CEST and perfusion imaging.

Results obtained with the 3.4 mm imaging protocol show good delineation of brain structures. At 2.5 mm ultra-high resolution there is increased gray-white matter contrast of metabolites due to less partial volume effect which reveals the brain folding more clearly than at 3.4 mm. Several metabolites show particularly high contrast between gray and white matter in healthy brain, such as the energy buffer tCre, the neurotransmitter Glu, and the dipeptide NAAG. In particular, NAAG is the most abundant dipeptide in the brain, which is selectively localized in several regions (Pouwels & Frahm, 1998) where it neuromodulates the glutamatergic synapses required for normal brain activity. Importantly, NAAG is also implicated in neurodegenerative diseases, schizophrenia, stroke, epilepsy, traumatic brain injury and pain (Morland & Nordengen, 2022). Our data show the highest resolution of 3D imaging for NAAG to date. 3D ECCENTRIC FID-MRSI provides images of NAAG brain distribution, which could offer valuable insights into both basic and clinical neuroscience questions. Good-quality metabolic images are obtained also for some of the most important but challenging metabolites such as GABA, Gln, and GSH. The combination of higher SNR and narrower linewidth (FWHM) results in lower CRLB for GABA, Gln, and GSH. The potential of short-echo FID spectra to detect GABA, Gln, and GSH at ultra-high field is supported also by previous findings reported in 9.4T studies (Nassirpour, Chang, & Henning, 2018a; Ziegs et al., 2023). Here, we extend the imaging of NAAG, GABA, Gln and GSH from single-slice to whole-brain and show that this is feasible at 7T which is more available for ultra-high field human imaging compared to 9.4T. As the 7T scanners have gained approval by regulatory agencies worldwide, the 7T imaging has reached clinical use and we expect ECCENTRIC will have a great contribution in clinical studies.

While correlation coefficients between the ground truth and accelerated ECCENTRIC acquisitions generally exhibit lower values for metabolic imaging (Fig. 4) compared to water imaging (Fig. 3; Supplementary Fig. S13), visual assessments indicate that the quality of metabolite mapping in the healthy brain is consistently preserved across all acceleration levels. Notably, the discrepancy between the results for metabolites and water images arises from the fact that, unlike water images where correlation coefficients are directly determined from reconstructed images, the correlation coefficients for metabolic images are influenced by additional processing steps such as water removal, fat removal, and LCModel fitting. These additional processing steps of MRSI data introduce variability that contributes to the lower correlation coefficients observed in metabolic imaging results.

The 3D ECCENTRIC FID-MRSI showed robust performance in healthy volunteers. The low variability in repeat measurements indicates high precision of metabolite quantification and significant potential for longitudinal studies to detect metabolite changes due to disease, treatment and functional tests. The high quality of the data was achieved through the use of third-order shimming, which provides more uniform B0 field across the brain, as well as the shortened scan time, which minimized the scanner drift and possibility of subject motion. The scanner drift typically ranged from 5–10 Hz over a 10 min scan time.

ECCENTRIC encoding is highly versatile with flexible choice of FoV, spatial resolution, and spectral bandwidth that can be set to optimize SNR and acquisition time. The advantage and strength of ECCENTRIC is enabled by the possibility to freely choose the radius and position of circle trajectories in covering the k-space: 1) the free choice of circle radius allows freedom in setting FoV, spatial resolution, and spectral bandwidth without the need of temporal interleaving, 2) the free choice of circle center position allows freedom for random undersampling the k-space to accelerate acquisition by CS. This flexibility is particularly important for 1H-MRSI at 7T and beyond, due to the increased spectral bandwidth required which limits the duration of k-space trajectories. In addition, free choice of circle position should enable FoV with different extent along the axial dimensions for additional time saving, which cannot be achieved by concentric, rosette and spiral trajectories.

ECCENTRIC flexibility in setting FoV, resolution, and spectral bandwidth by varying the circle radius and CS undersampling to optimize SNR and acquisition time is shown in Supplementary Figures S14–S16. These results indicate that, when using the same image resolution and acquisition time, ECCENTRIC provides a higher SNR for protocols that use smaller circle radii and higher acceleration compared to protocols using larger circle radii and lower acceleration. This flexibility allows to adapt ECCENTRIC acquisition to resolutions required across a range of FoV. Although we demonstrated ECCENTRIC for human brain imaging, this method can be used for ultra-high resolution metabolic imaging of mice brain where submillimeter resolution is required for a centimeter FoV. ECCENTRIC sampling was specifically designed for MRSI SSE measurements, requiring a trajectory that is successively repeated at a high frequency. While this high-frequency repeated sampling is not a prerequisite for traditional MRI technique, certain imaging techniques may demand the rapid acquisition of successive echoes and could potentially benefit from ECCENTRIC sampling at UHF.

There are some limitations in the current implementation. In particular, reconstruction time of 3D ECCENTRIC data requires several hours. For example, using a 64×64×31 matrix size for 3.4 mm isotropic, the water removal step took 1 h, the CS-SENSE-LR reconstruction took 3 h on a GPU (or 12 h on a CPU), and the parallel LCModel fitting took 1 h on a high-performance server such as the Dell PowerEdge R7525 (with 64 cores of 2.9GHz and 128M cache, 512GB RAM, and 3 NVIDIA Ampere A40 GPUs). This computation time may be considered relatively long for routine clinical applications. Also, at the moment subject motion or scanner drift is not corrected during ECCENTRIC acquisition, which may increase the variability of metabolite quantification. The metabolite concentrations were not provided in absolute units such as millimolar but expressed in institutional units (I.U.) relative to the water reference, which still provides comparable values across subjects and scanners. We note that for absolute quantification of FID-MRSI data only the T1 relaxation correction is needed, while ultra-short (<1 ms) echo-time makes T2 relaxation negligible. Our current ECCENTRIC design restricts circle positioning to a stack-of-ECCENTRIC configuration without tilting or rotating the circles. While this simplifies reconstruction, it also limits exploration of more complex sampling schemes, such as fully tilted circles, which could enhance k-space sampling efficiency. However, implementing tilted circles in 3D k-space would pose practical challenges due to the significantly increased computational demands of a full 3D discrete Fourier transform. Nevertheless, alternative reconstruction methods, such as NUFFT-based gridding (Fessler, 2007), may offer solutions to overcome these limitations and enable more thorough exploration of sampling strategies in 3D k-space.

Artificial intelligence is reshaping the landscape of MR image reconstruction, demonstrating improved performance and enabling more efficient and sparser data acquisition (Lin et al., 2021). In the domain of MRSI, the application of deep learning for reconstruction is an evolving field, marked by notable progress in super-resolution reconstruction (Dong et al., 2022; Li et al., 2020), learned-subspace approaches (Lam et al., 2020), channel combination strategies (Motyka et al., 2021), and parallel MRSI methods (Nassirpour, Chang, & Henning, 2018b). These encouraging findings suggest that the integration of deep learning holds substantial potential to enhance reconstruction outcomes over the model-based CS-SENSE-LR reconstruction employed in this study. Such improvement may manifest in improved quality of metabolite maps or even enable higher AF, consequently leading to faster acquisition.

In summary, we have introduced ECCENTRIC an advanced acquisition-reconstruction method for MRSI that pushes the boundaries of spatial and temporal capabilities for in vivo metabolic imaging. Although here we specifically demonstrated ECCENTRIC for MRSI at 7T ultra-high field, this method is not limited to this field and could be used at higher (9.4T) and lower (3T) fields. When combined with FID-MRSI acquisition, ECCENTRIC has demonstrated outstanding performance in the comprehensive mapping of metabolites throughout the entire brain, encompassing crucial neurotransmitters such as Glu and GABA. Anticipating that ECCENTRIC will pave the way for novel advancements in neuroscience, we envision its potential to provide detailed insights into brain neurochemistry in both healthy and pathological conditions. This innovation is poised to address crucial questions and facilitate groundbreaking discoveries in both fundamental research and clinical studies.

Data can be obtained from the corresponding author (O.C.A.) upon request with institutional agreement for data sharing. 3D ECCENTRIC FID-MRSI sequence and reconstruction can be obtained from the corresponding author (A.K.) upon request for Siemens Healthcare MAGNETOM Terra / Terra.X MRI system.

All authors contributed to manuscript writing. A.K. contributed to project design, sequence development and implementation, reconstruction code, data acquisition, and data analysis; B.S., W.B., and L.H. contributed sequence development and implementation, and reconstruction code; S.C. contributed reconstruction code; C.S. contributed reconstruction code; B.R.R. contributed to project design; F.L. contributed to project design; and O.C.A contributed overall project design, sequence development and implementation, reconstruction code, data acquisition, and data analysis.

This work was funded by the U.S. National Institutes of Health through National Cancer Institute (NCI/NIH) grant R01CA211080 and R01CA255479 (O.C.A.), Swiss National Science Foundation grant IZSEZ0_188859 (A.K.), and by Austrian Science Fund (FWF): KLI 1106, P 34198 and J 4124 (B.S., L.H. and W.B.). This research used the imaging equipment at Athinoula A. Martinos Center for Biomedical Imaging provided by the Center for Functional Neuroimaging Technologies, P41EB015896, a P41 Biotechnology Resource Grant supported by the National Institute of Biomedical Imaging and Bioengineering (NIBIB), and National Institutes of Health.

A.K. is employed by Siemens Healthcare AG, Switzerland. The other authors have nothing to disclose.

Supplementary material for this article is available with the online version here: https://doi.org/10.1162/imag_a_00313

Adalsteinsson
,
E.
,
Irarrazabal
,
P.
,
Topp
,
S.
,
Meyer
,
C.
,
Macovski
,
A.
, &
Spielman
,
D. M.
(
1998
).
Volumetric spectroscopic imaging with spiral-based k-space trajectories
.
Magnetic Resonance in Medicine
,
39
(
6
),
889
898
. https://doi.org/10.1002/mrm.1910390606
An
,
Z.
,
Tiwari
,
V.
,
Ganji
,
S. K.
,
Baxter
,
J.
,
Levy
,
M.
,
Pinho
,
M. C.
,
Pan
,
E.
,
Maher
,
E. A.
,
Patel
,
T. R.
,
Mickey
,
B. E.
, &
Choi
,
C.
(
2018
).
Echo-planar spectroscopic imaging with dual-readout alternated gradients (DRAG-EPSI) at 7T: Application for 2-hydroxyglutarate imaging in glioma patients
.
Magnetic Resonance in Medicine
,
79
,
1851
1861
. https://doi.org/10.1002/mrm.26884
Andronesi
,
O. C.
,
Bhattacharyya
,
P. K.
,
Bogner
,
W.
,
Choi
,
I. Y.
,
Hess
,
A. T.
,
Lee
,
P.
,
Meintjes
,
E. M.
,
Tisdall
,
M. D.
,
Zaitzev
,
M.
, &
van der Kouwe
,
A.
(
2021
).
Motion correction methods for MRS: Experts’ consensus recommendations
.
NMR in Biomedicine
,
34
,
e4364
. https://doi.org/10.1002/nbm.4364
Ban
,
F.
,
Woodruff
,
D.
, &
Zhang
,
Q.
(
2019
).
Regularized weighted low rank approximation
.
arXiv
. https://doi.org/10.48550/arXiv.1911.06958
Barkhuijsen
,
H.
,
de Beer
,
R.
, &
van Ormondt
,
D.
(
1987
).
Improved algorithm for noniterative time-domain model fitting to exponentially damped magnetic resonance signals
.
Journal of Magnetic Resonance (1969)
,
73
(
3
),
553
557
. https://doi.org/10.1016/0022-2364(87)90023-0
Bednarik
,
P.
,
Goranovic
,
D.
,
Svatkova
,
A.
,
Niess
,
F.
,
Hingerl
,
L.
,
Strasser
,
B.
,
Deelchand
,
D. K.
,
Spurny-Dworak
,
B.
,
Krssak
,
M.
,
Trattnig
,
S.
,
Hangel
,
G.
,
Scherer
,
T.
,
Lanzenberger
,
R.
, &
Bogner
,
W.
(
2023
).
1H magnetic resonance spectroscopic imaging of deuterated glucose and of neurotransmitter metabolism at 7T in the human brain
.
Nature Biomedical Engineering
,
7
,
1001
1013
. https://doi.org/10.1038/s41551-023-01035-z
Boer
,
V. O.
,
Klomp
,
D. W. J.
,
Juchem
,
C.
,
Luijten
,
P. R.
, &
de Graaf
,
R. A.
(
2012
).
Multislice 1H MRSI of the human brain at 7T using dynamic B0 and B1 shimming
.
Magnetic Resonance in Medicine
,
68
,
662
670
. https://doi.org/10.1002/mrm.23288
Bogner
,
W.
,
Gagoski
,
B.
,
Hess
,
A. T.
,
Bhat
,
H.
,
Tisdall
,
M. D.
,
van der Kouwe
,
A. J. W.
,
Strasser
,
B.
,
Marjańska
,
M.
,
Trattnig
,
S.
,
Grant
,
E.
,
Rosen
,
B.
, &
Andronesi
,
O. C.
(
2014
).
3D GABA imaging with real-time motion correction, shim update and reacquisition of adiabatic spiral MRSI
.
NeuroImage
,
103
,
290
302
. https://doi.org/10.1016/j.neuroimage.2014.09.032
Bogner
,
W.
,
Gruber
,
S.
,
Trattnig
,
S.
, &
Chmelík
,
M.
(
2012
).
High-resolution mapping of human brain metabolites by free induction decay 1H MRSI at 7 T
.
NMR in Biomedicine
,
25
(
6
),
873
882
. https://doi.org/10.1002/nbm.1805
Bogner
,
W.
,
Otazo
,
R.
, &
Henning
,
A.
(
2021
).
Accelerated MR spectroscopic imaging—A review of current and emerging techniques
.
NMR in Biomedicine
,
34
,
e4314
. https://doi.org/10.1002/nbm.4314
Candes
,
E.
,
Romberg
,
J.
, &
Tao
,
T.
(
2006
).
Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information
.
IEEE Transactions on Information Theory
,
52
(
2
),
489
509
. https://doi.org/10.1109/TIT.2005.862083
Chatnuntawech
,
I.
,
Gagoski
,
B.
,
Bilgic
,
B.
,
Cauley
,
S. F.
,
Setsompop
,
K.
, &
Adalsteinsson
,
E.
(
2015
).
Accelerated 1H MRSI using randomly undersampled spiral-based k-space trajectories
.
Magnetic Resonance in Medicine
,
74
(
1
),
13
24
. https://doi.org/10.1002/mrm.25394
Chiew
,
M.
,
Jiang
,
W.
,
Burns
,
B.
,
Larson
,
P.
,
Steel
,
A.
,
Jezzard
,
P.
,
Thomas
,
M. A.
, &
Emir
,
U. E.
(
2018
).
Density-weighted concentric rings k-space trajectory for 1H magnetic resonance spectroscopic imaging at 7T
.
NMR in Biomedicine
,
31
,
e3838
. https://doi.org/10.1002/nbm.3838
Davis
,
K. M.
,
Ryan
,
J. L.
,
Aaron
,
V. D.
, &
Sims
,
J. B.
(
2020
).
PET and SPECT imaging of the brain: History, technical considerations, applications, and radiotracers
.
Seminars in ultrasound, CT, and MR
,
41
,
521
529
. https://doi.org/10.1053/j.sult.2020.08.006
Derenzo
,
S. E.
,
Budinger
,
T. F.
,
Cahoon
,
J. L.
,
Huesman
,
R. H.
, &
Jackson
,
H. G.
(
1977
).
High resolution computed tomography of positron emitters
.
IEEE Transactions on Nuclear Science
,
24
(
1
),
544
558
. https://doi.org/10.1109/TNS.1977.4328738
Dillinger
,
H.
,
Peereboom
,
S. M.
, &
Kozerke
,
S.
(
2024
).
Beat phenomena of oscillating readouts
.
Magnetic Resonance in Medicine
,
91
,
1498
1511
. https://doi.org/10.1002/mrm.29957
Dong
,
S.
,
Bogner
,
W.
,
Widhalm
,
G.
,
Rössler
,
K.
,
Trattnig
,
S.
,
You
,
C.
,
de Graaf
,
R.
,
Onofrey
,
J. A.
,
Duncan
,
J. S.
, &
Hangel
,
G.
(
2022
).
Multi-scale super-resolution magnetic resonance spectroscopic imaging with adjustable sharpness
. In
L.
Wang
,
Q.
Dou
,
P. T.
Fletcher
,
S.
Speidel
, &
S.
Li
(Eds.),
Medical Image Computing and Computer Assisted Intervention—MICCAI 2022
(pp.
410
420
).
Springer
. https://doi.org/10.1007/978-3-031-16446-0_39
Donoho
,
D.
(
2006
).
Compressed sensing
.
IEEE Transactions on Information Theory
,
52
(
4
),
1289
1306
. https://doi.org/10.1109/TIT.2006.871582
Ebel
,
A.
,
Maudsley
,
A. A.
,
Weiner
,
M. W.
, &
Schuff
,
N.
(
2005
).
Achieving sufficient spectral bandwidth for volumetric 1H echo-planar spectroscopic imaging at 4 Tesla
.
Magnetic Resonance in Medicine
,
54
,
697
701
. https://doi.org/10.1002/mrm.20593
Esmaeili
,
M.
,
Strasser
,
B.
,
Bogner
,
W.
,
Moser
,
P.
,
Wang
,
Z.
, &
Andronesi
,
O. C.
(
2021
).
Whole-slab 3D MR spectroscopic imaging of the human brain with spiral-out-in sampling at 7T
.
Journal of Magnetic Resonance Imaging
,
53
,
1237
1250
. https://doi.org/10.1002/jmri.27437
Fessler
,
J. A.
(
2007
).
On NUFFT-based gridding for non-Cartesian MRI
.
Journal of Magnetic Resonance
,
188
,
191
195
. https://doi.org/10.1016/j.jmr.2007.06.012
Fischl
,
B.
,
Salat
,
D. H.
,
Busa
,
E.
,
Albert
,
M.
,
Dieterich
,
M.
,
Haselgrove
,
C.
,
van der Kouwe
,
A.
,
Killiany
,
R.
,
Kennedy
,
D.
,
Klaveness
,
S.
,
Montillo
,
A.
,
Makris
,
N.
,
Rosen
,
B.
, &
Dale
,
A. M.
(
2002
).
Whole brain segmentation
.
Neuron
,
33
(
3
),
341
355
. https://doi.org/10.1016/S0896-6273(02)00569-X
Furuyama
,
J. K.
,
Wilson
,
N. E.
, &
Thomas
,
M. A.
(
2012
).
Spectroscopic imaging using concentrically circular echo-planar trajectories in vivo
.
Magnetic Resonance in Medicine
,
67
,
1515
1522
. https://doi.org/10.1002/mrm.23184
Gruber
,
M. H. J.
, &
Hayes
,
M. H.
(
1997
).
Statistical digital signal processing and modeling
.
Technometrics
,
39
(
3
),
335
. https://doi.org/10.2307/1271141
Hangel
,
G.
,
Cadrien
,
C.
,
Lazen
,
P.
,
Furtner
,
J.
,
Lipka
,
A.
,
Hečková
,
E.
,
Hingerl
,
L.
,
Motyka
,
S.
,
Gruber
,
S.
,
Strasser
,
B.
,
Kiesel
,
B.
,
Mischkulnig
,
M.
,
Preusser
,
M.
,
Roetzer
,
T.
,
Wöhrer
,
A.
,
Widhalm
,
G.
,
Rössler
,
K.
,
Trattnig
,
S.
, &
Bogner
,
W.
(
2020
).
High-resolution metabolic imaging of high-grade gliomas using 7T-CRT-FID-MRSI
.
NeuroImage: Clinical
,
28
,
102433
. https://doi.org/10.1016/j.nicl.2020.102433
Hangel
,
G.
,
Strasser
,
B.
,
Považan
,
M.
,
Heckova
,
E.
,
Hingerl
,
L.
,
Boubela
,
R.
,
Gruber
,
S.
,
Trattnig
,
S.
, &
Bogner
,
W.
(
2018
).
Ultra-high resolution brain metabolite mapping at 7 T by short-TR Hadamard-encoded FID-MRSI
.
NeuroImage
,
168
,
199
210
. https://doi.org/10.1016/j.neuroimage.2016.10.043
Henning
,
A.
,
Fuchs
,
A.
,
Murdoch
,
J. B.
, &
Boesiger
,
P.
(
2009
).
Slice-selective FID acquisition, localized by outer volume suppression (FIDLOVS) for 1H-MRSI of the human brain at 7T with minimal signal loss
.
NMR in Biomedicine
,
22
,
683
696
. https://doi.org/10.1002/nbm.1366
Hingerl
,
L.
,
Bogner
,
W.
,
Moser
,
P.
,
Považan
,
M.
,
Hangel
,
G.
,
Heckova
,
E.
,
Gruber
,
S.
,
Trattnig
,
S.
, &
Strasser
,
B.
(
2018
).
Density-weighted concentric circle trajectories for high resolution brain magnetic resonance spectroscopic imaging at 7T
.
Magnetic Resonance in Medicine
,
79
(
6
),
2874
2885
. https://doi.org/10.1002/mrm.26987
Hingerl
,
L.
,
Strasser
,
B.
,
Moser
,
P.
,
Hangel
,
G.
,
Motyka
,
S.
,
Heckova
,
E.
,
Gruber
,
S.
,
Trattnig
,
S.
, &
Bogner
,
W.
(
2020
).
Clinical high-resolution 3D-MR spectroscopic imaging of the human brain at 7 T
.
Investigative Radiology
,
55
(
4
),
239
248
. https://doi.org/10.1097/RLI.0000000000000626
Hu
,
S.
,
Lustig
,
M.
,
Balakrishnan
,
A.
,
Larson
,
P. E. Z.
,
Bok
,
R.
,
Kurhanewicz
,
J.
,
Nelson
,
S. J.
,
Goga
,
A.
,
Pauly
,
J. M.
, &
Vigneron
,
D. B.
(
2010
).
3D compressed sensing for highly accelerated hyperpolarized 13C MRSI with in vivo applications to transgenic mouse models of cancer
.
Magnetic Resonance in Medicine
,
63
(
2
),
312
321
. https://doi.org/10.1002/mrm.22233
Hu
,
S.
,
Lustig
,
M.
,
Chen
,
A. P.
,
Crane
,
J.
,
Kerr
,
A.
,
Kelley
,
D. A. C.
,
Hurd
,
R.
,
Kurhanewicz
,
J.
,
Nelson
,
S. J.
,
Pauly
,
J. M.
, &
Vigneron
,
D. B.
(
2008
).
Compressed sensing for resolution enhancement of hyperpolarized 13C flyback 3D-MRSI
.
Journal of Magnetic Resonance
,
192
,
258
264
. https://doi.org/10.1016/j.jmr.2008.03.003
Iqbal
,
Z.
,
Wilson
,
N. E.
, &
Thomas
,
M. A.
(
2016
).
3D spatially encoded and accelerated TE-averaged echo planar spectroscopic imaging in healthy human brain
.
NMR in Biomedicine
,
29
(
3
),
329
339
. https://doi.org/10.1002/NBM.3469
Jiang
,
W.
,
Lustig
,
M.
, &
Larson
,
P. E. Z.
(
2016
).
Concentric rings k-space trajectory for hyperpolarized (13)C MR spectroscopic imaging
.
Magnetic Resonance in Medicine
,
75
,
19
31
. https://doi.org/10.1002/mrm.25577
Kampf
,
T.
,
Fischer
,
A.
,
Basse-Lüsebrink
,
T. C.
,
Ladewig
,
G.
,
Breuer
,
F.
,
Stoll
,
G.
,
Jakob
,
P. M.
, &
Bauer
,
W. R.
(
2010
).
Application of compressed sensing to in vivo 3D 19F CSI
.
Journal of Magnetic Resonance
,
207
,
262
273
. https://doi.org/10.1016/j.jmr.2010.09.006
Kim
,
D.-H.
, &
Spielman
,
D. M.
(
2006
).
Reducing gradient imperfections for spiral magnetic resonance spectroscopic imaging
.
Magnetic Resonance in Medicine
,
56
,
198
203
. https://doi.org/10.1002/mrm.20928
Klauser
,
A.
,
Courvoisier
,
S.
,
Kasten
,
J.
,
Kocher
,
M.
,
Guerquin-Kern
,
M.
,
Van De Ville
,
D.
, &
Lazeyras
,
F.
(
2019
).
Fast high-resolution brain metabolite mapping on a clinical 3T MRI by accelerated 1H-FID-MRSI and low-rank constrained reconstruction
.
Magnetic Resonance in Medicine
,
81
(
5
),
2841
2857
. https://doi.org/10.1002/mrm.27623
Klauser
,
A.
,
Klauser
,
P.
,
Grouiller
,
F.
,
Courvoisier
,
S.
, &
Lazeyras
,
F.
(
2022
).
Whole-brain high-resolution metabolite mapping with 3D compressed-sensing sense low-rank 1H FID-MRSI
.
NMR in Biomedicine
,
35
,
e4615
. https://doi.org/10.1002/nbm.4615
Klauser
,
A.
,
Strasser
,
B.
,
Thapa
,
B.
,
Lazeyras
,
F.
, &
Andronesi
,
O.
(
2021
).
Achieving high-resolution 1H-MRSI of the human brain with compressed-sensing and low-rank reconstruction at 7 Tesla
.
Journal of Magnetic Resonance
,
331
,
107048
. https://doi.org/10.1016/J.JMR.2021.107048
Knoll
,
F.
,
Bredies
,
K.
,
Pock
,
T.
, &
Stollberger
,
R.
(
2011
).
Second order total generalized variation (TGV) for MRI
.
Magnetic Resonance in Medicine
,
65
(
2
),
480
491
. https://doi.org/10.1002/mrm.22595
Knoll
,
F.
,
Clason
,
C.
,
Diwoky
,
C.
, &
Stollberger
,
R.
(
2011
).
Adapted random sampling patterns for accelerated MRI
.
Magnetic Resonance Materials in Physics, Biology and Medicine
,
24
(
1
),
43
50
. https://doi.org/10.1007/s10334-010-0234-7
Lam
,
F.
,
Li
,
Y.
,
Guo
,
R.
,
Clifford
,
B.
, &
Liang
,
Z. P.
(
2020
).
Ultrafast magnetic resonance spectroscopic imaging using SPICE with learned subspaces
.
Magnetic Resonance in Medicine
,
83
(
2
),
377
390
. https://doi.org/10.1002/mrm.27980
Li
,
X.
,
Strasser
,
B.
,
Jafari-Khouzani
,
K.
,
Thapa
,
B.
,
Small
,
J.
,
Cahill
,
D. P.
,
Dietrich
,
J.
,
Batchelor
,
T. T.
, &
Andronesi
,
O. C.
(
2020
).
Super-resolution whole-brain 3D MR spectroscopic imaging for mapping D-2-hydroxyglutarate and tumor metabolism in isocitrate dehydrogenase 1–mutated human gliomas
.
Radiology
,
294
,
589
597
. https://doi.org/10.1148/radiol.2020191529
Lin
,
D. J.
,
Johnson
,
P. M.
,
Knoll
,
F.
, &
Lui
,
Y. W.
(
2021
).
Artificial intelligence for MR image reconstruction: An overview for clinicians
.
Journal of Magnetic Resonance Imaging
,
53
,
1015
1028
. https://doi.org/10.1002/jmri.27078
Ma
,
C.
,
Lam
,
F.
,
Johnson
,
C. L.
, &
Liang
,
Z. P.
(
2016
).
Removal of nuisance signals from limited and sparse1H MRSI data using a union-of-subspaces model
.
Magnetic Resonance in Medicine
,
75
(
2
),
488
497
. https://doi.org/10.1002/mrm.25635
Mareci
,
T. H.
, &
Brooker
,
H.
(
1991
).
Essential considerations for spectral localization using indirect gradient encoding of spatial information
.
Journal of Magnetic Resonance (1969)
,
92
(
2
),
229
246
. https://doi.org/10.1016/0022-2364(91)90267-W
Marques
,
J. P.
,
Kober
,
T.
,
Krueger
,
G.
,
van der Zwaag
,
W.
,
de Moortele
,
P. F. V.
, &
Gruetter
,
R.
(
2010
).
MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field
.
NeuroImage
,
49
,
1271
1281
. https://doi.org/10.1016/J.NEUROIMAGE.2009.10.002
Matsui
,
S.
,
Sekihara
,
K.
, &
Kohno
,
H.
(
1985
).
High-speed spatially resolved NMR spectroscopy using phase-modulated spin-echo trains. expansion of the spectral bandwidth by combined use of delayed spin-echo trains
.
Journal of Magnetic Resonance (1969)
,
64
,
167
171
. https://doi.org/10.1016/0022-2364(85)90047-2
Maudsley
,
A. A.
,
Andronesi
,
O. C.
,
Barker
,
P. B.
,
Bizzi
,
A.
,
Bogner
,
W.
,
Henning
,
A.
,
Nelson
,
S. J.
,
Posse
,
S.
,
Shungu
,
D. C.
, &
Soher
,
B. J.
(
2020
).
Advanced magnetic resonance spectroscopic neuroimaging: Experts’ consensus recommendations
.
NMR in Biomedicine
,
34
(
5
),
e4309
. https://doi.org/10.1002/nbm.4309
Michael
,
L.
,
Donoho
,
D.
, &
Paulyv
,
J. M.
(
2007
).
Sparse MRI: The application of compressed sensing for rapid MR imaging
.
Magnetic Resonance in Medicine
,
58
(
6
),
1182
1195
. https://doi.org/10.1002/mrm.21391
Morland
,
C.
, &
Nordengen
,
K.
(
2022
).
N-acetyl-aspartyl-glutamate in brain health and disease
.
International Journal of Molecular Sciences
,
23
(
3
),
1268
. https://doi.org/10.3390/ijms23031268
Moser
,
P.
,
Bogner
,
W.
,
Hingerl
,
L.
,
Heckova
,
E.
,
Hangel
,
G.
,
Motyka
,
S.
,
Trattnig
,
S.
, &
Strasser
,
B.
(
2019
).
Non-Cartesian GRAPPA and coil combination using interleaved calibration data—Application to concentric-ring MRSI of the human brain at 7T
.
Magnetic Resonance in Medicine
,
82
(
5
),
1587
1603
. https://doi.org/10.1002/mrm.27822
Motyka
,
S.
,
Hingerl
,
L.
,
Strasser
,
B.
,
Hangel
,
G.
,
Heckova
,
E.
,
Agibetov
,
A.
,
Dorffner
,
G.
,
Gruber
,
S.
,
Trattning
,
S.
, &
Bogner
,
W.
(
2021
).
K-space-based coil combination via geometric deep learning for reconstruction of non-Cartesian MRSI data
.
Magnetic Resonance in Medicine
,
86
,
2353
2367
. https://doi.org/10.1002/MRM.28876
Mullins
,
P. G.
(
2018
).
Towards a theory of functional magnetic resonance spectroscopy (fMRS): A meta-analysis and discussion of using MRS to measure changes in neurotransmitters in real time
.
Scandinavian Journal of Psychology
,
59
(
1
),
91
103
. https://doi.org/10.1111/sjop.12411
Nam
,
K. M.
,
Gursan
,
A.
,
Bhogal
,
A. A.
,
Wijnen
,
J. P.
,
Klomp
,
D. W. J.
,
Prompers
,
J. J.
, &
Hendriks
,
A. D.
(
2023
).
Deuterium echo-planar spectroscopic imaging (EPSI) in the human liver in vivo at 7 T
.
Magnetic Resonance in Medicine
,
90
,
863
874
. https://doi.org/10.1002/mrm.29696
Nam
,
K. M.
,
Hendriks
,
A. D.
,
Boer
,
V. O.
,
Klomp
,
D. W.
,
Wijnen
,
J. P.
, &
Bhogal
,
A. A.
(
2022
).
Proton metabolic mapping of the brain at 7T using a two-dimensional free induction decay–echo-planar spectroscopic imaging readout with lipid suppression
.
NMR in Biomedicine
,
35
,
e4771
. https://doi.org/10.1002/nbm.4771
Nassirpour
,
S.
,
Chang
,
P.
,
Avdievitch
,
N.
, &
Henning
,
A.
(
2018
).
Compressed sensing for high-resolution nonlipid suppressed 1H FID MRSI of the human brain at 9.4T
.
Magnetic Resonance in Medicine
,
80
(
6
),
2311
2325
. https://doi.org/10.1002/mrm.27225
Nassirpour
,
S.
,
Chang
,
P.
, &
Henning
,
A.
(
2018a
).
High and ultra-high resolution metabolite mapping of the human brain using 1H FID MRSI at 9.4T
.
NeuroImage
,
168
,
211
221
. https://doi.org/10.1016/j.neuroimage.2016.12.065
Nassirpour
,
S.
,
Chang
,
P.
, &
Henning
,
A.
(
2018b
).
MultiNet PyGRAPPA: Multiple neural networks for reconstructing variable density GRAPPA (a 1H FID MRSI study)
.
NeuroImage
,
183
,
336
345
. https://doi.org/10.1016/j.neuroimage.2018.08.032
Ogg
,
R. J.
,
Kingsley
,
P. B.
, &
Taylor
,
J. S.
(
1994
).
WET, a T1- and B1-insensitive water-suppression method for in vivo localized 1H NMR spectroscopy
.
Journal of Magnetic RSesonance. Series B
,
104
(
1
),
1
10
. https://doi.org/10.1006/jmrb.1994.1048
Otazo
,
R.
,
Lin
,
F.-H.
,
Wiggins
,
G.
,
Jordan
,
R.
,
Sodickson
,
D.
, &
Posse
,
S.
(
2009
).
Superresolution parallel magnetic resonance imaging: Application to functional and spectroscopic imaging
.
NeuroImage
,
47
,
220
230
. https://doi.org/10.1016/j.neuroimage.2009.03.049
Otazo
,
R.
,
Mueller
,
B.
,
Ugurbil
,
K.
,
Wald
,
L.
, &
Posse
,
S.
(
2006
).
Signal-to-noise ratio and spectral linewidth improvements between 1.5 and 7 Tesla in proton echo-planar spectroscopic imaging
.
Magnetic Resonance in Medicine
,
56
(
6
),
1200
1210
. https://doi.org/10.1002/mrm.21067
Oz
,
G.
,
Alger
,
J. R.
,
Barker
,
P. B.
,
Bartha
,
R.
,
Bizzi
,
A.
,
Boesch
,
C.
,
Bolan
,
P. J.
,
Brindle
,
K. M.
,
Cudalbu
,
C.
,
Dinçer
,
A.
,
Dydak
,
U.
,
Emir
,
U. E.
,
Frahm
,
J.
,
González
,
R. G.
,
Gruber
,
S.
,
Gruetter
,
R.
,
Gupta
,
R. K.
,
Heerschap
,
A.
,
Henning
,
A.
, …
Kauppinen
,
R. A.
(
2014
).
Clinical proton MR spectroscopy in central nervous system disorders
.
Radiology
,
270
(
3
),
658
679
. https://doi.org/10.1148/radiol.13130531
Pauly
,
J.
,
Roux
,
P. L.
,
Nishimura
,
D.
, &
Macovski
,
A.
(
1991
).
Parameter relations for the shinnar-le roux selective excitation pulse design algorithm [NMR imaging]
.
IEEE Transactions on Medical Imaging
,
10
,
53
65
. https://doi.org/10.1109/42.75611
Posse
,
S.
,
DeCarli
,
C.
, &
Bihan
Le
, D
. (
1994
).
Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain
.
Radiology
,
192
(
3
),
733
738
. https://doi.org/10.1148/radiology.192.3.8058941
Posse
,
S.
,
Otazo
,
R.
,
Caprihan
,
A.
,
Bustillo
,
J.
,
Chen
,
H.
,
Henry
,
P. G.
,
Marjanska
,
M.
,
Gasparovic
,
C.
,
Zuo
,
C.
,
Magnotta
,
V.
,
Mueller
,
B.
,
Mullins
,
P.
,
Renshaw
,
P.
,
Ugurbil
,
K.
,
Lim
,
K. O.
, &
Alger
,
J. R.
(
2007
).
Proton echo-planar spectroscopic imaging of J-coupled resonances in human brain at 3 and 4 Tesla
.
Magnetic Resonance in Medicine
,
58
,
236
244
. https://doi.org/10.1002/mrm.21287
Pouwels
,
P. J.
, &
Frahm
,
J.
(
1998
).
Regional metabolite concentrations in human brain as determined by quantitative localized proton MRS
.
Magnetic Resonance in Medicine
,
39
,
53
60
. https://doi.org/10.1002/mrm.1910390110
Provencher
,
S. W.
(
1993
).
Estimation of metabolite concentrations from localized in vivo proton NMR spectra
.
Magnetic Resonance in Medicine
,
30
(
6
),
672
679
. https://doi.org/10.1002/mrm.1910300604
Rasche
,
V.
,
Proksa
,
R.
,
Sinkus
,
R.
,
Börnert
,
P.
, &
Eggers
,
H.
(
1999
).
Resampling of data between arbitrary grids using convolution interpolation
.
IEEE Transactions on Medical Imaging
,
18
(
5
),
385
392
. https://doi.org/10.1109/42.774166
Santos-Díaz
,
A.
, &
Noseworthy
,
M. D.
(
2019
).
Comparison of compressed sensing reconstruction algorithms for 31P magnetic resonance spectroscopic imaging
.
Magnetic Resonance Imaging
,
59
,
88
96
. https://doi.org/10.1016/j.mri.2019.03.006
Saucedo
,
A.
,
Macey
,
P. M.
, &
Thomas
,
M. A.
(
2021
).
Accelerated radial echo-planar spectroscopic imaging using golden angle view-ordering and compressed-sensing reconstruction with total variation regularization
.
Magnetic Resonance in Medicine
,
86
(
1
),
46
61
. https://doi.org/10.1002/mrm.28728
Schirda
,
C. V.
,
Tanase
,
C.
, &
Boada
,
F. E.
(
2009
).
Rosette spectroscopic imaging: Optimal parameters for alias-free, high sensitivity spectroscopic imaging
.
Journal of Magnetic Resonance Imaging
,
29
(
6
),
1375
1385
. https://doi.org/10.1002/jmri.21760
Schirda
,
C. V.
,
Zhao
,
T.
,
Yushmanov
,
V. E.
,
Lee
,
Y.
,
Ghearing
,
G. R.
,
Lieberman
,
F. S.
,
Panigrahy
,
A.
,
Hetherington
,
H. P.
, &
Pan
,
J. W.
(
2018
).
Fast 3D rosette spectroscopic imaging of neocortical abnormalities at 3 T: Assessment of spectral quality
.
Magnetic Resonance in Medicine
,
79
(
5
),
2470
2480
. https://doi.org/10.1002/mrm.26901
Smith
,
S.
,
Levante
,
T.
,
Meier
,
B.
, &
Ernst
,
R.
(
1994
).
Computer simulations in magnetic resonance. An object-oriented programming approach
.
Journal of Magnetic Resonance, Series A
,
106
(
1
),
75
105
. https://doi.org/10.1006/jmra.1994.1008
Strasser
,
B.
,
Považan
,
M.
,
Hangel
,
G.
,
Hingerl
,
L.
,
Chmelík
,
M.
,
Gruber
,
S.
,
Trattnig
,
S.
, &
Bogner
,
W.
(
2017
).
(2+1)D-CAIPIRINHA accelerated MR spectroscopic imaging of the brain at 7T
.
Magnetic Resonance in Medicine
,
78
(
2
),
429
440
. https://doi.org/10.1002/mrm.26386
Uecker
,
M.
,
Lai
,
P.
,
Murphy
,
M. J.
,
Virtue
,
P.
,
Elad
,
M.
,
Pauly
,
J. M.
,
Vasanawala
,
S. S.
, &
Lustig
,
M.
(
2014
).
ESPIRIT—An eigenvalue approach to autocalibrating parallel MRI: Where sense meets grappa
.
Magnetic Resonance in Medicine
,
71
(
3
),
990
1001
. https://doi.org/10.1002/mrm.24751
Versteeg
,
E.
,
Nam
,
K. M.
,
Klomp
,
D. W. J.
,
Bhogal
,
A. A.
,
Siero
,
J. C. W.
, &
Wijnen
,
J. P.
(
2024
).
A silent echo-planar spectroscopic imaging readout with high spectral bandwidth MRSI using an ultrasonic gradient axis
.
Magnetic Resonance in Medicine
,
91
,
2247
2256
. https://doi.org/10.1002/mrm.30008
Weng
,
G.
,
Radojewski
,
P.
,
Sheriff
,
S.
,
Kiefer
,
C.
,
Schucht
,
P.
,
Wiest
,
R.
,
Maudsley
,
A. A.
, &
Slotboom
,
J.
(
2022
).
SLOW: A novel spectral editing method for whole-brain MRSI at ultra high magnetic field
.
Magnetic Resonance in Medicine
,
88
(
1
),
53
70
. https://doi.org/10.1002/mrm.29220
Xu
,
Z.
,
Niedzielski
,
J. S.
,
Sun
,
C.
,
Walker
,
C. M.
,
Michel
,
K. A.
,
Einstein
,
S. A.
,
Martinez
,
G. V.
, &
Bankson
,
J. A.
(
2020
).
Correction and optimization of symmetric echo-planar spectroscopic imaging for hyperpolarized [1-13c]-pyruvate
.
Journal of Magnetic Resonance
,
321
,
106859
. https://doi.org/10.1016/j.jmr.2020.106859
Ziegs
,
T.
,
Wright
,
A. M.
, &
Henning
,
A.
(
2023
).
Test–retest reproducibility of human brain multi-slice 1H FID-MRSI data at 9.4T after optimization of lipid regularization, macromolecular model, and spline baseline stiffness
.
Magnetic Resonance in Medicine
,
89
,
11
28
. https://doi.org/10.1002/mrm.29423
This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International (CC BY 4.0) license, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. For a full description of the license, please visit https://creativecommons.org/licenses/by/4.0/legalcode.

Supplementary data